YSI_Prog_E - 第108页

2-37 2 Creating inspection pr ograms 4 Set the deplo yment conditions. Select the direction to be copied from the "Prior Direction" drop-down list. Select the condition check boxes as required. [View Copy] scre…

100%1 / 226
2-36
2
Creating inspection programs
n
Pitch input and copy of multiple views
Use the [Pitch Deploy] button to copy multiple views such as for creating views on a multi-board panel.
1
Select the views to be copied.
Select multiple views to be copied in the view radar.
2
Press the [Pitch Deploy] button.
The "View Copy" dialog box appears.
[Pitch Deploy] button
[Pitch Deploy] button
View list
View radar
24235-P6-00
3
Enter the number of copies and the pitch.
Enter the number of copies in the "Number XY" boxes, and enter the pitch in the "Pitch XY" boxes.
n
NOTE
When setting the pitch to create multiple views on a multi-board panel, enter the view pitch data by board design.
(Units: mm)
2-37
2
Creating inspection programs
4
Set the deployment conditions.
Select the direction to be copied from the "Prior Direction" drop-down list. Select the condition check
boxes as required.
[View Copy] screen
Set the deployment conditions.
Step 3
24236-P6-00
Prior direction
Select the prior direction to be copied.
Prior direction
X direction Y direction
23216-P6-00
Set Block No. Automatically
Select this check box to add a block No. to the deployed view.
Fid Collect Addition
By selecting this check box, fiducials recognized when deploying the view are corrected.
5
Press the [OK] button to perform copy.
6
Click on the view list and view radar.
The copied views are displayed on the screen.
Screen example after pitch input and copy
Before pitch input and copy After pitch input and copy
Views are copied in
the specified positions
24237-P6-00
2-38
2
Creating inspection programs
2.7 Step settings
A "step" is the minimum inspection unit, and inspection details and judgment conditions are set for each step.
Combinations of steps used to inspect each parts are used as parts libraries. With inspection programs
converted from YAMAHA mounter data (YGX), parts libraries stored in the inspection machine are deployed to
mounter mounting positions. For parts to which no libraries have been deployed, it is necessary to paste the
relevant libraries from the parts library, create and register new libraries, and then deploy them.
n
NOTE
A parts library is a database to which a combination of inspection steps for each parts has been saved.
2.7.1 Pasting libraries
Paste standard libraries to parts for which libraries have not been deployed.
1
Press the [Data Edit] button and open the "Step" tab.
2
Press the [Lib Non Set] button in the "Utility" tab.
Parts for which libraries have not been deployed appear in the "Library Non Set Parts List".
Library Non Set Parts List
Parts for which libraries
have not been deployed
24238-P6-00
3
Select a part and press the [Close] button.
Move to the applicable part.
4
Press the [Paste] button at the "Tuning" tab.
A "Library Selection" screen appears.
[Library Selection] screen
24239-P6-00