YSI_Prog_E - 第119页
2-48 2 Creating inspection pr ograms 2.7.5 Checking libraries Existing libraries ha ve been set for inspection of standard parts, and therefore it ma y sometimes be necessary to change the settings based on the actual in…

2-47
2
Creating inspection programs
6
Set the deployment conditions.
Select the deployment conditions as required.
No changes to OCR
By selecting this check box, the inspection character string for character recognition when deploying
the library is not changed.
Set LibParts from library table file
By selecting this check box, the library selected in the library table is deployed.
7
Press the [Execute] button to deploy.
Information registered by "LibParts"is deployed for all relevant parts. The deployment status and
deployment result appear at the bottom of the screen.
8
Press the [Close] button to end deployment.
The display returns to the "Step" screen.

2-48
2
Creating inspection programs
2.7.5 Checking libraries
Existing libraries have been set for inspection of standard parts, and therefore it may sometimes be necessary to
change the settings based on the actual inspection parts. This section describes the procedure used to perform
a test (multi-test) for deployed parts libraries.
1
Select the part for the library to be checked.
2
Press the [Multi] button at the "Tuning" tab.
A multi-test screen appears.
3
Press the [Condition] button to select the test conditions.
Select a value for each item from the drop-down lists. When selection is complete, press the [OK] button
to return to the multi-test screen.
[Multi-test] screen
Test conditions setting
[Condition] button
Select values from drop-down lists.
24254-P6-00
Test Subject
Select the test subject from Step, Inspection Status, Parts, or NG reason.
Test condition
Select from All, Same Lib Parts Name, Same Parts Name, and Same Ref. No.
Test range
Select from All, Only Piece of Board, Only Selected View, and Only Selected Parts.
Test Board side
Select Side A, Side B, or both.
Image List Test
Select from All, Skip, OK Images only, or NG Images only.
Library Image
Select from Skip, Exec OK parts , Exec NG Parts, and Exec all .
4
Press the [Execute] button.
The test results for all steps matching the selected conditions are displayed in a list.
5
Change all parameter settings.
Click steps judged to be NG, and select the relevant step. In order that the step be judged correctly,
change parameters such as step detection conditions and judgment conditions. For details on all
inspection status settings, see Chapter 4, "Inspection status", in this manual.
TIP
By pressing the [Analysis] button, a "Detect Value Graph" screen appears.
Select the "Display item" and display the test result in a graph as a reference to help with parameter correction.

2-49
2
Creating inspection programs
2.7.6 Saving view images
If the steps do not fit inside the view for the deployed library, create the view again and save the image.
1
Create the view again.
Press the [Data Edit] button, open the "View" tab, and press the "Auto Creation" function [Auto] button.
Follow the instructions in the dialog box that appears.
2
Save the view image.
Open the image list "OK Image" tab, select "Standard Image", and press the [OverWrite] button.
3
Save the created inspection program.
Press the button area [Save] button.