YSI_Prog_E - 第176页

4-16 4 Inspection status 1.6 Lead Check Use this inspection mode to chec k for solder bridges between leads or between adjacent parts. 1 Make a "step" setting. 1. Create a step frame. 2. Open the "Basic&qu…

100%1 / 226
4-15
4
Inspection status
3
Set the "Judge" parameters.
Open the "Judge" tab and set the following parameters.
"Judge" parameters
Status: Solder Quantity Check
24421-P6-00
Offset Limit N - W (mm)
These are not normally used and should be set to "SKIP".
Min Area (%)
If the ratio of the detected area to the standard area is smaller than the value set here, then an NG
occurs.
Ref. value 30%
Max Area (%)
An NG result is judged if the ratio relative to the standard area for the detected area exceeds this
value.
Ref. value 120%
4
Perform a step test.
1. Press the [Step] button at the "Tuning" tab to perform a test for the created step.
2. Take a note of and check the detection data, and then press the [End] button.
Screen after a step test is finished
Test resultDisplays detected data.
24422-P6-00
Detected data
dx =, dy = : Amount that the step frame center deviates from the detection area center
Threshold No. : Threshold No. used for inspection
Area = : Percentage of the detected area relative to the standard area
3. If the test result is not judged correctly, review all parameters while referring to the detection data.
4-16
4
Inspection status
1.6 Lead Check
Use this inspection mode to check for solder bridges between leads or between adjacent parts.
1
Make a "step" setting.
1. Create a step frame.
2. Open the "Basic" tab, and set the "Status" in the basic parameters to "Lead Check".
3. Open the "LIGHT" tab, and set the light sampling type and threshold value in the lighting parameters
so that leads and solder are shown in red.
Sampling light type reference: Luminance
Status (Inspection mode)
Lead Check
Set to "Lead Check".
Step frame
24423-P6-00
2
Set the "Judge" parameters.
Open the "Judge" tab and set the following parameters.
"Judge" parameters
Status: Lead Check
24424-P6-00
Offset Limit N - W (mm)
This should normally be set to "SKIP".
If a value is entered, an NG result is judged if the recognized edge exceeds this value.
Pin Number Check
Select "SKIP" from the drop-down list, or enter the number of pins.
Select "SKIP".
Use to inspect bridges between leads on ICs and connectors without inspecting the number of pins.
Enter the number of inspection pins.
The number of pins is inspected. This is used to inspect bridges between leads of 3-pin or 5-pin
transistors, etc., and to inspect 180° mounting displacements. An NG test result is judged if other than
this value.
4-17
4
Inspection status
Min Area, Max Area (%)
Sets the minimum and maximum area for the OK detection area. Sets based on the value set at "Pin
Number Check". An NG test result is judged if the inspection object lies outside the range for the value
set here.
If "SKIP" is selected for "Pin Number Check"
Min Area reference value: SKIP, Max Area reference value: 100
If the number of inspection pins is entered at "Pin Number Check"
Min Area reference value: 10 to 30, Max Area reference value: 100
Lead Space Check (mm)
This parameter is not normally used and should be set to "SKIP". If using this parameter, set it to the
default setting of "0.06".
3
Set the "Detect" parameters.
Open the "Detect" tab and set the following parameters.
"Detect" parameters
Status: Lead Check
[基準面積]ボタン
24425-P6-00
Std Area (mm
2
)
Sets the step area. Sets based on the value set for "Pin Number Check" at the "Judge" tab.
If "Pin Number Check" is set to "SKIP", enter "4". If the number of inspection pins has not been entered,
press the [Area] button to acquire.
Min Detect Size (mm)
Enter the minimum size for the object to be inspected.
4
Perform a step test.
1. Press the [Step] button at the "Tuning" tab to perform a test for the created step.
2. When the test result appears, press the [End] button. When doing so, there is no problem if the test
result is "NG".
5
Press the [Detail] button.
The "Inspect result" dialog box opens. Press the [Auto Calculation] button. The following items in the
Judgment condition parameters are set automatically.
Maximum Acceptable Size X, Y (mm)
A value 1.5 times the maximum recognition value is set.
An NG test result is judged if the inspection object exceeds this value.
Lead Space Check (mm)
70% of the minimum recognition width is set. (only when set between leads)
An NG test result is judged if the distance between leads on the inspection object exceeds this value.