5-9
5
Inspection machine settings
2.1 Installation settings
Installation settings are used to specify default machine settings.
"Machine settings" screen
"Setting" m "Machine Information" m"Installation Setting" 1/2
3
1
2
24510-P6-00
Item Details
1
Basic Brand Displays the brand name of this machine.
Machine Type Displays the machine type.
Sub Machine Type Displays the sub machine type.
Serial No. Displays the machine serial No.
Machine Name
Enter the machine name appended to data sent to the Repair
Station (option).
OS Language Sets the OS language used.
2
Function Setting Inspection Mode
Select the inspection mode for automatic inspection from "AUTO" or
SEMI-AUTO".
• AUTO
Performs board inspection to the end, and then displays details of
any defects.
• SEMI-AUTO
Inspection is terminated the moment a defect is detected during
board inspection, and the defect location displays on the NG
monitor. Judgment is made while viewing defect location images.
Counter is initialized
after program loading
When set to "Use", the total production quantity is initialized to "0"
when reading inspection data.
Inspection skip of NG
parts
Selects the steps to be skipped when an NG occurs.
• NON
Inspection is not skipped.
• Ref unit
Steps from the same Ref. No. onward are skipped.
• Pin unit
Steps from the same Pin. No. onward are skipped.
X-ray Source Auto Self
Test
When set to "Enable", a self test is performed after the X-ray source
warm-up is complete.
3
Image Setting OK,NG Image Quality
Selects the file format for saving images from "JPG" or "BMP".
"JPG" should normally be selected. If "BMP" is selected, inspection
images can be saved as is, however, the time required to save
images is longer than that for "JPG", and more space is required.
Inspection will stop if there is insufficient backup space, and
therefore caution is advised.
Image Auto SAVE
Select whether to automatically save inspection images from "No
Use", "Ng Image", or "All".
• No Use
Does not automatically save inspection images.
• Ng Image
Saves NG view images and fiducial mark images to the
"NgImage" folder contained in the inspection data folder when an
NG occurs.
• All Image
Saves all view images and fiducial mark images.
MAX Collection
Sets the maximum number of boards that can be saved to a
program.
5-10
5
Inspection machine settings
"Machine settings" screen
"Setting" m "Machine Information" m "Installation Setting" 2/2
5
6
4
7
8
9
24511-P6-00
Item Details
4
Periodic Light Check Cycle
Set to perform a periodic lighting check. Select from "No Use",
"Daily", or "Weekly".
Start Time
Specifies the lighting check start time when "Daily" or "Weekly" is
selected for the "Cycle".
Week
Specifies the day on which the lighting check is performed when
"Weekly" is selected for the "Cycle".
5 Vision
Wating Timer for
Sampling (mm)
Displays the time until image capture is started after the camera or
conveyor (YSi-X) moves.
6
X-Ray (YSi-X) X-Ray source Type Displays the X-ray source installed on the machine.
Image Join (Standard
Only)
Enables multiple X-ray image composition when set to "Use".
X-Ray Zoom Enables the capture of enlarged X-ray images when set to "Use".
X-Ray Tilt sight Enables the capture of tilted X-ray images when set to "Use".
X-Ray Shading Data
Update Cycle (min)
Sets the cycle for X-ray shading.
7
Conveyor Fixed Conveyor Displays the standard conveyor when changing the conveyor width.
AUTO Width Adjustment
If "ON" is displayed, the conveyor width is changed when reading
the program. If "OFF" is displayed, the conveyor width is not
changed when reading the program.
ConvFlowDirection Displays the conveyor flow direction.
Board Cooling (sec) Sets the waiting time at the conveyor entrance for board cooling.
Board Wating Timer
(msec)
Specifies the conveyor idling time until the board is clamped after
hitting the stopper when performing board loading.
Carry Out Timer (msec) Specifies the conveyor idling time when unloading boards.
Upper Handing
Sets the specification for the transfer of board signals with the
upstream machine.*
Lower Handing
Sets the specification for the transfer of board signals with the
downstream machine.*
NG Stop
Stops the machine and sets the timing of the message output when
an NG board occurs during automatic inspection.
Select from "No Use", "Before Export", and "After Export".
• No Use
This function is not used.
• Before Export
Displays a message at the inspection position.
• After Export
Displays a message after unloading the board from the machine.
Transter Mode
Sets the board transfer method from "NORMAL", "DEMO U-TURN",
or "DEMO Fixed".
NG Stocker Type
Selects the NG stocker type if equipped with an NG stocker. Select
"Through" if not equipped with an NG stocker.
5-11
5
Inspection machine settings
Item Details
8
Maker Maker Unit Set to "Use" if the machine is equipped with a marking unit (option).
Maker Unit Type Sets the existence of a pen cap.
Ink Check Interval
(markings)
Sets the friction check interval with the number of boards.
9 Laser Laser Unit
Set to "Use" if the machine is equipped with a laser height sensor
(option).
* Signals can be checked during automatic inspection at the [Auto] - "Conveyor" tab. Furthermore, "T01000" can be output at
the conveyor at the [Unit] - "I/O" tab.
2.2 Conveyor transfer settings
Conveyor transfer settings are used to set the board loading and unloading positions and so on.
"Machine settings" screen
"Setting" m "Machine Information" m "Conveyor Setting"
1
2
24512-P6-00
Item
Details
Auto Manual
When performing automatic
inspection
When performing manual
inspection
1
Board Transter
control
IN Sets the board entrance.
OUT Sets the board exit.
NG CONT Sets the board exit when NG results continue.
Cancel Sets the board exit when inspection is canceled.
2 Monitor Post-Process
Downstream signals are monitored when the check box is selected.
An alarm occurs if no "Busy In" signal is input from downstream
even when the timeout time is exceeded.