YSI_Prog_E - 第61页

1-26 1  asic operation 2. Star ting and ending inspection 2.1 Star ting automatic inspection c  Ensure to complete conveyor unit setup before starting automatic inspection.  …

100%1 / 226
1-25
1
asic operation
1.8 Operator selection screen
Pressing the [Operators] tab opens an "ID WINDOW" screen.
The machine operator is selected at this screen.
TIP
Operation items differ depending on the selected operator level. For details on items displayed in the "ID WINDOW"
screen, refer to Chapter 5, "1. Operator management", in this manual.
[Operator] – [ID WINDOW] screen
1
3
4 5
2
24125-P6-00
Item/button name Description
1 GROUP NAME Selects the group name for operators performing operation.
2 OPERATOR NAME Selects the name of the operator performing operation.
3 PASSWORD
Used to enter the password if one is specified for the operator performing
operation. Press the [OK] button if no password has been specified.
4 OK
The operation screen appears if the password is correct, allowing inspection
machine operation.
5 Cancel Cancels operation.
1-26
1
asic operation
2. Starting and ending inspection
2.1 Starting automatic inspection
c

Ensure to complete conveyor unit setup before starting automatic inspection.

2.1.1 Selecting inspection programs
1
Press the [Setup] button.
The "Program Change" screen opens.
2
Load the program from the inspection program list.
To load an inspection program, either select a program from the list and press the [Select] button, or
double-click a program in the list directly.
Selecting inspection programs
YSi-X screen example
[Setup] button
[Select] button
Select the inspection program.
24126-P6-00
3
Verify the loaded inspection program.
The loaded inspection program name appears in the status area.
1-27
1
asic operation
2.1.2 Starting automatic inspection
1
Check the inspection program.
Check the inspection program name displayed in the "Status" area of the screen.
2
Press the [Auto] button in the "Button" area.
The "Auto inspection" screen opens to enter automatic inspection mode.
3
Press the [Run] button to start inspection.
To stop the automatic inspection, press the [Stop] button.
Automatic inspection flow
Auto mode
Inspection
OK NG
[Auto] button
[Run] button
[Image List] button
[Stop] button
[Buzzer off] button
24117-P6-00
[Image List] button
A list of view captured images is displayed. If a board ID (image) is selected from this list, inspection can
be performed for the selected board ID (image).
[Buzzer OFF] button
Pressing the buzzer OFF button while the buzzer is sounding stops the buzzer.