4M-1751-005w_G5S - 第101页

4OM-1751 1-51 1304-001 4.12 Control Box Section Filter (1 location) Every 3 Months Cleaning Required T ime: 4 minutes (1) Remove the screws (3 locations) fixing the dust filter and remove the dust filter. (2) Suck dirt a…

100%1 / 339
4OM-1751
1-501304-001
Cam Follower
Every Month Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Shutter Flange Pin Sliding Section
Every 3 Months Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Required Time: 5 minutes
(1) Wipe off old grease with an oiled rag.
(2) Apply new grease with a syringe.
(1) Wipe off old grease with an oiled rag.
(2) Apply new grease by hand or with a
brush.
Use No. 19 (brown) nozzle.
No.19
Note
Take ample care not to
leave the waste threads
after the old grease is
wiped off.
Shutter Flange Pin Sliding Section
Every 3 Months Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Required Time: 5 minutes
(1) Wipe off old grease with an oiled rag.
(2) Apply new grease with a syringe.
Use No. 19 (brown) nozzle.
No.19
Note
Notice
F4A43
4.11 Nozzle Stocker Section
4OM-1751
1-511304-001
4.12 Control Box Section
Filter (1 location)
Every 3 Months Cleaning
Required Time: 4 minutes
(1) Remove the screws (3 locations) fixing the
dust filter and remove the dust filter.
(2) Suck dirt and dust with a vacuum cleaner.
(3) Attach the dust filter.
F4A44
4.12 Control Box Section
4OM-1751
1-52
4.13 Fans Section
Every 3 Months Cleaning
Required Time: 10 minutes
Suck dirt and dust from the dust filters with
a vacuum cleaner.
Ventilating Fan (3 locations)
F4A45
1304-001
4.13 Fans Section