Error ID Error Name, Description, Cause, and Remedy
438306 Tray Feeder Zeroing Error (Block1)
Feeder base is not in Upward position.
Please press READY switch on Feeder Base, and rise it after setting Feeder cart..
438402 Tray Feeder Zeroing Error (Block1)
Time-out of Unclamp operating of Elevator Unit.
-----
438403 Tray Feeder Zeroing Error (Block1)
Feeder base is not in Upward position.
Please press READY switch on Feeder Base, and rise it after setting Feeder cart..
438405 Tray Feeder Zeroing Error (Block1)
There were error when Tray receded.
-----
438406 Tray Feeder Zeroing Error (Block1)
There were error when elevator1(Down) receded.
-----
438407 Tray Feeder Zeroing Error (Block1)
There were error when elevator2(Up) receded.
-----
438408 Tray Feeder Zeroing Error (Block1)
There were error when traverse receded.
-----
438501 Tray Feeder Zeroing Error (Block1)
Time-out of waiting for initialization
Please conrm AE-LINK wiring and Power wiring.
438502 Tray Feeder Zeroing Error (Block1)
Can not communicate Driver.
Please conrm AE-LINK wiring and Power wiring.
438503 Tray Feeder Zeroing Error (Block1)
Communication Status Error(Stand by)
Please conrm AE-LINK wiring and Power wiring.
438504 Tray Feeder Zeroing Error (Block1)
Communication Status Error(Alarm)
Please conrm AE-LINK wiring and Power wiring.
438505 Tray Feeder Zeroing Error (Block1)
Communication Status Error(OT)
Please conrm AE-LINK wiring and Power wiring.
438506 Tray Feeder Zeroing Error (Block1)
Communication Status Error(Connection O)
Please conrm AE-LINK wiring and Power wiring.
438507 Tray Feeder Zeroing Error (Block1)
Communication Status Error(Driver Alarm)
Please conrm AE-LINK wiring and Power wiring.
438508 Tray Feeder Zeroing Error (Block1)
Communication Status Error(SV-net stopping)
Please conrm AE-LINK wiring and Power wiring.
3.4 Tray Feeder (Block1)
4OM-1751
3-631701-005
Error ID Error Name, Description, Cause, and Remedy
438509 Tray Feeder Zeroing Error (Block1)
Communication Status Error(Out of Connection number)
Please conrm AE-LINK wiring and Power wiring.
43850A Tray Feeder Zeroing Error (Block1)
Communication Status Error(SV-VET Error)
Please conrm AE-LINK wiring and Power wiring.
43850B Tray Feeder Zeroing Error (Block1)
Failed to read the number of Axes
Please conrm AE-LINK wiring and Power wiring.
43850C Tray Feeder Zeroing Error (Block1)
Driver-axis is not connected.
Please conrm AE-LINK wiring and Power wiring.
43850D Tray Feeder Zeroing Error (Block1)
Elevator1-axis is not connected.
Please conrm AE-LINK wiring and Power wiring.
43850E Tray Feeder Zeroing Error (Block1)
Elevator2-aixs in not connected.
Please conrm AE-LINK wiring and Power wiring.
438510 Tray Feeder Zeroing Error (Block1)
Motor Breaker Trip Error
-----
438511 Tray Feeder Zeroing Error (Block1)
Elevator Unit is not connected.
Please connect Elevator unit in Unit exchange menu.
438512 Tray Feeder Zeroing Error (Block1)
All connectors of Elevator Unit are not connected.
Please conrm the connection to all connector of Elevator Unit
438513 Tray Feeder Zeroing Error (Block1)
Failed to start-up Communication of SV-NET.
Please conrm AE-LINK wiring and Power wiring.
438514 Tray Feeder Zeroing Error (Block1)
Failed to turn on Tray.(Time-out)
-----
438515 Tray Feeder Zeroing Error (Block1)
(At nishing Auto Run) Tray operation(Block1) is not completed within a specied
time.
Please push Emergency Stop button.
438516 Tray Feeder Zeroing Error (Block1)
To discriminate the connected tray cart is failed.
Please press READY switch on Feeder Base again. Please contact to the service
when to output the error is continuous.
438517 Tray Feeder Zeroing Error (Block1)
Timeout in discriminating the tray cart.
Please press READY switch on Feeder Base again. Please contact to the service
when to output the error is continuous.
3.4 Tray Feeder (Block1)
4OM-1751
3-641701-005
Error ID Error Name, Description, Cause, and Remedy
438601 Tray (Servo Error) (Block1)
Error of Power Driver, Over-current
Please conrm Motor wiring, Exchange Motor and Driver.
438602 Tray (Servo Error) (Block1)
Overload Alarm
Please conrm Motor wiring, Exchange Motor and Driver.
438603 Tray (Servo Error) (Block1)
Speed Alarm
You need to re-adjust Motor Gain.
438604 Tray (Servo Error) (Block1)
Multi-rotation Error
Please conrm Motor wiring, Exchange Motor and Driver.
438605 Tray (Servo Error) (Block1)
The value of Deviation Counter was over the set value
Please conrm the wiring of Origin Sensor, or exchange Driver.
438606 Tray (Servo Error) (Block1)
Power Drive detected temperature error.
Ambient Temperature is too high. Or, exchange driver.
438607 Tray (Servo Error) (Block1)
Sensor Error
Please conrm Motor Encoder wiring. Or, exchange motor
438608 Tray (Servo Error) (Block1)
High Drive voltage
Insucient power capacity. Please exchange driver.
438609 Tray (Servo Error) (Block1)
Low drive voltage
Please conrm the operating Power wiring which is inserted to driver.
43860A Tray (Servo Error) (Block1)
Reading Error on permanent memory
Please exchange driver.
43860B Tray (Servo Error) (Block1)
Reading Error on permanent memory
Please exchange driver.
43860C Tray (Servo Error) (Block1)
CPU Error
Please exchange driver.
43860D Tray (Servo Error) (Block1)
Parameter Error
Please conrm the changed parameter.
43860E Tray (Servo Error) (Block1)
Alarm code readout failed
-----
438701 Elevator Recede position operating error (Block1)
Elevator pre-check error
-----
3.4 Tray Feeder (Block1)
4OM-1751
3-651701-005