4M-1751-005w_G5S - 第270页

3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 600410 Head Rotate center oset teach Error when L-axis began zeroing ----- 60041 1 Head Rotate center oset teach Error while L-axis is on zeroing …

100%1 / 339
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600401 Head Rotate center oset teach
Can not recognize Glass Jig
Please conrm that Glass Jig is set on Glass Jig place.(Check it because there is
a possibility that nozzle is not on head, or vacuum is not "ON".)
600402 Head Rotate center oset teach
Error of Recognition Command response.
-----
600403 Head Rotate center oset teach
Error of coordinates calculation.
-----
600404 Head Rotate center oset teach
Error when Jig pickup began
-----
600405 Head Rotate center oset teach
Error in the movement of Jig pickup
-----
600406 Head Rotate center oset teach
Error when Jig store began
-----
600407 Head Rotate center oset teach
Error in the movement of Jig store
-----
600408 Head Rotate center oset teach
Error when HL-axis and NL-axis began zeroing.
-----
600409 Head Rotate center oset teach
Error while HL-axis and NL-axis are on zeroing
-----
60040a Head Rotate center oset teach
Error when DD-axis began to rotate
-----
60040b Head Rotate center oset teach
Error while DD-axis is rotating
-----
60040c Head Rotate center oset teach
Error of Data set for XY Beam.
-----
60040d Head Rotate center oset teach
Error of moving for XY Beam.
-----
60040e Head Rotate center oset teach
Time-out in XY Beam
-----
60040f Head Rotate center oset teach
Time-out of communication with recognition
-----
4OM-1751
3-1381701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600410 Head Rotate center oset teach
Error when L-axis began zeroing
-----
600411 Head Rotate center oset teach
Error while L-axis is on zeroing
-----
600412 Head Rotate center oset teach
Error when Z-axis began to rotate
-----
600413 Head Rotate center oset teach
Error while Z-axis is rotating
-----
600414 Head Rotate center oset teach
Error when L-axis began to drop
-----
600415 Head Rotate center oset teach
Error when L-axis is dropping
-----
600416 Head Rotate center oset teach
-----
-----
600501 Reference mark position teach
Could not recognize Glass Jig in CTR Fly Recognition.
Please conrm that Glass Jig is set on Glass Jig place.(Check it because there is
a possibility that nozzle is not on head, or vacuum is not "ON".)
600502 Reference mark position teach
Error of Recognition Command response in case of CTR Fly Recognition
-----
600503 Reference mark position teach
Could not recognize Standard Mark
-----
600504 Reference mark position teach
Error of Recognition Command response in case of Standard Mark Recognition
-----
600505 Reference mark position teach
Error of coordinates calculation of CTR Fly Recognition
-----
600506 Reference mark position teach
Error when Jig pickup of CTR Fly Recognition began
-----
600507 Reference mark position teach
Error of the movement of Jig pickup of CTP Fly Recognition
-----
600508 Reference mark position teach
Error when Jig store of CTR Fly Recognition began
-----
4OM-1751
3-1391701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600509 Reference mark position teach
Error of the movement of Jig store of CTR Fly Recognition
-----
60050a Reference mark position teach
Error when HL-axis, NL-axis of CTR Fly Recognition began zeroing.
-----
60050b Reference mark position teach
Error while HL-axis, NL-axis of CTR Fly Recognition is zeroing.
-----
60050c Reference mark position teach
Error when DD-axis of CTR Fly Recognition began to rotate.
-----
60050d Reference mark position teach
Error while DD-axis of CTR Fly Recognition is rotating.
-----
60050e Reference mark position teach
Error of Data set for XY Beam of CTR Fly Recognition
-----
60050f Reference mark position teach
Error of moving for XY Beam.
-----
600510 Reference mark position teach
Time-out in XY Beam movement
-----
600511 Reference mark position teach
Time-out in communication with Recognition
-----
600512 Reference mark position teach
Error of coordinates calculation of Standard Mark Recognition
-----
600513 Reference mark position teach
Error of moving for XY Beam.
-----
600514 Reference mark position teach
Time-out in XY Beam movement
-----
600515 Reference mark position teach
Time out in communication with Recognition
-----
600601 Nozzle position oset teach
Could not recognize nozzle
Please conrm that Nozzle is placed and exact Nozzle arrangement data is set.
600602 Nozzle position oset teach
Error of Recognition Command response.
-----
4OM-1751
3-1401701-005