4M-1751-005w_G5S - 第272页

3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 600603 Nozzle position oset teach Error of coordinates calculation. ----- 600604 Nozzle position oset teach Error when DD-axis began to rotate. --…

100%1 / 339
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600509 Reference mark position teach
Error of the movement of Jig store of CTR Fly Recognition
-----
60050a Reference mark position teach
Error when HL-axis, NL-axis of CTR Fly Recognition began zeroing.
-----
60050b Reference mark position teach
Error while HL-axis, NL-axis of CTR Fly Recognition is zeroing.
-----
60050c Reference mark position teach
Error when DD-axis of CTR Fly Recognition began to rotate.
-----
60050d Reference mark position teach
Error while DD-axis of CTR Fly Recognition is rotating.
-----
60050e Reference mark position teach
Error of Data set for XY Beam of CTR Fly Recognition
-----
60050f Reference mark position teach
Error of moving for XY Beam.
-----
600510 Reference mark position teach
Time-out in XY Beam movement
-----
600511 Reference mark position teach
Time-out in communication with Recognition
-----
600512 Reference mark position teach
Error of coordinates calculation of Standard Mark Recognition
-----
600513 Reference mark position teach
Error of moving for XY Beam.
-----
600514 Reference mark position teach
Time-out in XY Beam movement
-----
600515 Reference mark position teach
Time out in communication with Recognition
-----
600601 Nozzle position oset teach
Could not recognize nozzle
Please conrm that Nozzle is placed and exact Nozzle arrangement data is set.
600602 Nozzle position oset teach
Error of Recognition Command response.
-----
4OM-1751
3-1401701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600603 Nozzle position oset teach
Error of coordinates calculation.
-----
600604 Nozzle position oset teach
Error when DD-axis began to rotate.
-----
600605 Nozzle position oset teach
Error while DD-axis is rotating
-----
600606 Nozzle position oset teach
Error when HL-axis and NL-axis began zeroing
-----
600607 Nozzle position oset teach
Error while HL-axis and NL-axis are on zeroing
-----
600608 Nozzle position oset teach
Error of Data set for XY Beam.
-----
600609 Nozzle position oset teach
Error of moving for XY Beam.
-----
60060a Nozzle position oset teach
Time-out in XY Beam movement
-----
60060b Nozzle position oset teach
Time-out in communication with Recognition
-----
600701 Fly recog. Oset teach
Could not recognize Standard Mark Stop
-----
600702 Fly recog. Oset teach
Could not recognize Standard Mark Fly
-----
600703 Fly recog. Oset teach
Error of Recognition Command Responses in a case of Head Stop Recognition
-----
600704 Fly recog. Oset teach
Error of Recognition Command Responses in a case of Fly Recognition
-----
600705 Fly recog. Oset teach
Error of Coordinates calculation
-----
600706 Fly recog. Oset teach
Error of Data set for XY Beam.
-----
4OM-1751
3-1411701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Oset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Oset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Oset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
-----
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
Please exchange Feeder
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle oset
Could not recognize Glass Jig
Please conrm that Glass Jig is set on Glass Jig place.(Check it because there is
a possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle oset
Error of Recognition Command Response
-----
4OM-1751
3-1421701-005