4M-1751-005w_G5S - 第273页

3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 600707 Fly recog. Oset teach Error of moving for XY Beam. ----- 600708 Fly recog. Oset teach T ime-out in XY Beam movement ----- 600709 Fly recog.…

100%1 / 339
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600603 Nozzle position oset teach
Error of coordinates calculation.
-----
600604 Nozzle position oset teach
Error when DD-axis began to rotate.
-----
600605 Nozzle position oset teach
Error while DD-axis is rotating
-----
600606 Nozzle position oset teach
Error when HL-axis and NL-axis began zeroing
-----
600607 Nozzle position oset teach
Error while HL-axis and NL-axis are on zeroing
-----
600608 Nozzle position oset teach
Error of Data set for XY Beam.
-----
600609 Nozzle position oset teach
Error of moving for XY Beam.
-----
60060a Nozzle position oset teach
Time-out in XY Beam movement
-----
60060b Nozzle position oset teach
Time-out in communication with Recognition
-----
600701 Fly recog. Oset teach
Could not recognize Standard Mark Stop
-----
600702 Fly recog. Oset teach
Could not recognize Standard Mark Fly
-----
600703 Fly recog. Oset teach
Error of Recognition Command Responses in a case of Head Stop Recognition
-----
600704 Fly recog. Oset teach
Error of Recognition Command Responses in a case of Fly Recognition
-----
600705 Fly recog. Oset teach
Error of Coordinates calculation
-----
600706 Fly recog. Oset teach
Error of Data set for XY Beam.
-----
4OM-1751
3-1411701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600707 Fly recog. Oset teach
Error of moving for XY Beam.
-----
600708 Fly recog. Oset teach
Time-out in XY Beam movement
-----
600709 Fly recog. Oset teach
Time-out of communication with recognition
-----
600801 Teaching Pick-up Position
Please push the Feeder Ready SW
-----
600802 Teaching Pick-up Position
Error of Feeder Mark Recognition
-----
600803 Teaching Pick-up Position
Feeder connection is set in test mode.
Please set test pattern "OK"
600804 Teaching Pick-up Position
The data of the feeder was not able to be read.
Please exchange Feeder
600805 Teaching Pick-up Position
Time-over of Feeder Mark Recognition Process
-----
600806 Teaching Pick-up Position
Time-out in XY Beam movement
-----
600807 Teaching Pick-up Position
Error of moving for XY Beam.
-----
600808 Teaching Pick-up Position
Error of processing Recognition Stop
-----
600809 Teaching Pick-up Position
Error of processing Light on
-----
60080a Teaching Pick-up Position
Error of processing image capture
-----
600901 Teaching Leaning Nozzle oset
Could not recognize Glass Jig
Please conrm that Glass Jig is set on Glass Jig place.(Check it because there is
a possibility that nozzle is not on head, or vacuum is not "ON".)
600902 Teaching Leaning Nozzle oset
Error of Recognition Command Response
-----
4OM-1751
3-1421701-005
3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
600903 Teaching Leaning Nozzle oset
Error of coordinates calculation.
-----
600904 Teaching Leaning Nozzle oset
Error of Data set for XY Beam.
-----
600905 Teaching Leaning Nozzle oset
Error of moving for XY Beam.
-----
600906 Teaching Leaning Nozzle oset
Time-out in XY Beam movement
-----
600907 Teaching Leaning Nozzle oset
Time-out of communication with recognition.
-----
600908 Teaching Leaning Nozzle oset
Error of Leaning Nozzle oset teaching
-----
600909 Teaching Leaning Nozzle oset
Error of Noz Select Axis Pos. Oset Teaching
-----
60090A Teaching Leaning Nozzle oset
Noz Select Axis Pos. Oset is out of permission values.
There is a possibility that Head Rotate Theta Axis oset is not correct. / There is
a possibility that Light Emitter and Receiver of Linear measuring Sensor has aw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
60090B Teaching Leaning Nozzle oset
Could not measure correctly on Noz Select Axis Pos. Oset Teaching.
There is a possibility that Head Rotate Theta Axis oset is not correct. / There is
a possibility that Light Emitter and Receiver of Linear measuring Sensor has aw
and soil / There is a possibility that Nozzle is damaged. / There is a possibility that
Head has some problem.
601001 Master nozzle level oset teach
Error is detected before Line Sensor measurement began
-----
601002 Master nozzle level oset teach
Error of NS-axis movement
-----
601003 Master nozzle level oset teach
Error of DD-axis movement
-----
601004 Master nozzle level oset teach
Time-out of NS-axis movement
-----
4OM-1751
3-1431701-005