3.13 Auto T eaching Error ID Error Name, Description, Cause, and Remedy 601302 Noz stocker oset teaching Error of XY -axis movement ----- 601303 Noz stocker oset teaching T ime-out in XY -axis movement ----- 601304 Noz…

3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601005 Master nozzle level oset teach
Time-out of DD-axis movement
-----
601006 Master nozzle level oset teach
Time-out when Line Sensor measurement began
-----
601007 Master nozzle level oset teach
Read Time-out of Line Sensor measurement
-----
601101 Noz level oset teaching
Time-out when Line Sensor measurement began
-----
601102 Noz level oset teaching
Read Time-out of Line Sensor measurement
-----
601103 Noz level oset teaching
Error during Line Sensor measurement
-----
601104 Noz level oset teaching
Error of dirty Line Sensor
-----
601105 Noz level oset teaching
Error of NS-axis Origin calculation
-----
601106 Noz level oset teaching
Error of NS-axis movement
-----
601107 Noz level oset teaching
Error of DD-axis Origin Calculation
-----
601108 Noz level oset teaching
Error of DD-axis movement
-----
601109 Noz level oset teaching
Program Error
-----
60110a Noz level oset teaching
Error before Line Sensor measurement began
-----
60110b Noz level oset teaching
Nozzle on Head is not placed
-----
601301 Noz stocker oset teaching
Error of coordinates calculation(XY)
-----
4OM-1751
3-1441701-005

3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601302 Noz stocker oset teaching
Error of XY-axis movement
-----
601303 Noz stocker oset teaching
Time-out in XY-axis movement
-----
601304 Noz stocker oset teaching
Error of HL-axis movement
-----
601305 Noz stocker oset teaching
Error of NL-axis movement
-----
601306 Noz stocker oset teaching
Error of L-axis movement
-----
601307 Noz stocker oset teaching
Error of HL/NL/L-axis movement
-----
601308 Noz stocker oset teaching
Nozzle stocker is not clamped
-----
601309 Noz stocker oset teaching
Error of Lighting On of P.C.B. Recognition Camera
-----
60130a Noz stocker oset teaching
Timeout of Lighting On of P.C.B. Recognition Camera
-----
60130b Noz stocker oset teaching
Error of Lighting O of P.C.B. Recognition Camera
-----
60130c Noz stocker oset teaching
Time-out of Lighting O of P.C.B. Recognition Camera
-----
60130d Noz stocker oset teaching
Error of image capture of Nozzle Stocker Mark
-----
60130e Noz stocker oset teaching
Time-out of image capture of Nozzle Stocker Mark
-----
60130f Noz stocker oset teaching
Error of Recognition Performance of Nozzle Stocker Mark
-----
601310 Noz stocker oset teaching
Time-out of Recognition Performance of Nozzle Stocker Mark
-----
4OM-1751
3-1451701-005

3.13 Auto Teaching
Error ID Error Name, Description, Cause, and Remedy
601311 Noz stocker oset teaching
Error of output-movement of Nozzle Stocker
-----
601401 Teaching Comp. Recog. Camera Magnication Teach
Time-out of communication with recognition.
Is there Network with Recognition? Please check.
601402 Teaching Comp. Recog. Camera Magnication Teach
Error of Recognition Command response
-----
601a01 Linear measure sensor correction re-teach
The linear measure reading is abnormal.
Please conrm whether the nozzle has adhered to the position.
601a02 Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure sensor correction re-teach
Nozzle can not be detected.
-----
601a04 Linear measure sensor correction re-teach
Line Sensor Control is abnormal.
-----
601a05 Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/R-Err7)
-----
601a06 Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(All samples are E/NR-Err8)
Oset correction can not be completed. Please use the big nozzle(HA05) teach
-----
601a07 Linear measure sensor correction re-teach
again and adjust the light & receive optical Axis(Edge detect error-Err9)
-----
601a08 Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Insucient samples-Err10)
-----
601a09 Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach again
and adjust the light & receive optical Axis(Insucient correcting samples-Err14)
-----
601a0a Linear measure sensor correction re-teach
Oset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis(Fail to create correction-Err15)
-----
4OM-1751
3-1461701-005