4OM-1751 1-41 1304-001 Y -Axis Linear Guides (2 locations ) Every Day Inspection Required T ime: 1 minute Check visually for any dropped foreign substance, etc. Y -Axis Linear Guides (8 locations ) Every 3 Months Cleanin…

4OM-1751
1-401403-004
4.8 X/Y Beam Section
X-Axis Linear Guides (2 locations)
Every Day Inspection
Required Time: 1 minute
Check visually for any dropped foreign
substance, etc.
X-Axis Linear Guides (4 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Wipe off old grease with a rag and supply new
grease to the grease nipples with a hand grease
gun.
Take ample care not to leave
any waste threads after cleaning.
Grease should be applied every 3 months after
the initial month.
Notice
X-Axis Ball Screw (2 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 3)
Wipe off old grease with a rag and supply new
grease to the grease nipples with a hand grease
gun.
Take ample care not to leave
any waste threads after cleaning.
Grease should be applied every 3 months after
the initial month.
Notice
F4A33
4.8 X/Y Beam Section

4OM-1751
1-411304-001
Y-Axis Linear Guides (2 locations)
Every Day Inspection
Required Time: 1 minute
Check visually for any dropped foreign
substance, etc.
Y-Axis Linear Guides (8 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Wipe off old grease with a rag and supply new
grease to the grease nipples with a hand grease
gun.
Take ample care not to leave
any waste threads after cleaning.
Grease should be applied every 3 months after
the initial month.
Notice
F4A34
4.8 X/Y Beam Section

4OM-1751
1-421304-001
X-Axis Cable Fixing Places (2 locations)
Every 6 Months Inspection
Required Time: 1 minute
Check visually for any abnormality such as
cracks.
X-Axis Cable Side Faces
Every 6 Months Cleaning and Lubrication
(BARRIERTA IEL/V)
Required Time: 3 minutes
(1) Wipe off old grease with an oiled rag.
(2) Apply new grease by hand or with a brush.
Take ample care not to leave
any waste threads after
cleaning.
Notice
X-Axis Linear Scale
Every 6 Months Cleaning
Required Time: 5 minutes
When it is very dirty, clean it using a cloth
soaked in alcohol.
F4A35
4.8 X/Y Beam Section