00195346-0302_SM_WPC4_EN - 第100页
SITEST for WPC4 SITEST Lifting Axis Settings Teaching the Zer o P oint 100 Ser vice Manual SIPLACE WPC4 5.9.2 T eaching th e Zero Point Teach zero point... Opens a dialog box with a warning. Acknowledge this with OK an…

SITEST for WPC4
Stepping the Lifting Axis SITEST Lifting Axis Settings
Service Manual SIPLACE WPC4
99
5.9.1 Stepping the Lifting Axis
Acknowledge this with
OK
to open the following dialog box.
Arrow pointing upwards: Each time you click on this button, the lifting axis will be moved one step
of the selected step size upwards.
Arrow pointing downwards: Each time you click on this button, the lifting axis will be moved one
step of the selected step size downwards.
Step: This is where you can set the required step size for moving the lifting axis.
OK : Closes the dialog box. The lifting axis remains in the position it has moved to.
Cancel: Closes the dialog box. The procedure is terminated.
ATTENTION: Only use the function "Step lifting axis" if it is absolutely imperative.
For example, if a waffle pack tray carrier has jammed in the WPC, you will no longer be able to
move the lifting axis. With the help of the buttons in this dialog box, the lifting axis can be moved
stepwise up or down, until the error can be fixed. The lifting axis does not need to be referenced
for this.

SITEST for WPC4
SITEST Lifting Axis Settings Teaching the Zero Point
100 Service Manual SIPLACE WPC4
5.9.2 Teaching the Zero Point
Teach zero point... Opens a dialog box with a warning.
Acknowledge this with
OK
and the following dialog box will open, in which you can teach the zero point.
Arrow pointing upwards: Each time you click on this button, the lifting axis will be moved one step
of the selected step size upwards.
Arrow pointing downwards: Each time you click on this button, the lifting axis will be moved one
step of the selected step size downwards.
Current position: Shows the position of the lifting axis approached during teaching.
Step: This is where you can set the required step size for moving the lifting axis.
Accept: Saves the current position and closes the dialog box.
You can now start a reference run.
To start the reference run, confirm the dialog box shown with
OK
.
Cancel: Closes the dialog box without saving any changes made.

SITEST for WPC4
Teaching the Zero Point SITEST Machine Data
Service Manual SIPLACE WPC4
101
5.10 SITEST Machine Data
Menu field: Info
WPC serial number: Shows the WPC serial number.
WPC machine data: Shows the current status of the WPC machine data.
Menu field: Machine data
Initialize...: Opens a dialog box in which the WPC serial number can be entered.
Save WPC machine data...: Opens a dialog box in which you can save the WPC machine data as
a file, in a folder of your choice.
Restore WPC machine data... Opens a dialog box in which you can restore (import) the saved WPC
machine data.