00195346-0302_SM_WPC4_EN - 第58页
Replacing Spare Parts Limit Switches, Sensors and Light Barriers Replac ing th e R eference Sensor , Lifting Axis [03047278 -xx] 58 Ser vice Manual SIPLACE WPC4 X Perform the necessar y calib rations in SITEST, according…

Replacing Spare Parts
Replacing the Reference Sensor, Lifting Axis [03047278-xx] Limit Switches, Sensors and Light Barriers
Service Manual SIPLACE WPC4
57
3.6.9 Replacing the Reference Sensor, Lifting Axis [03047278-xx]
Settings
X Check the function and correct position of the reference sensor.
X To do this, open the SITEST main view and select the function=>
SITEST Settings
.
X In the input area
Axis
select
Lifting axis
.
X In the input area
Travel range
select
Reference bero
.
The lifting axis is moved, approaches the reference sensor and determines the reference point.
In the SITEST main view, function=>
SITEST inputs/outputs 1,
the display
Reference sensor,
lifting axis
will be activated.
A dialog box will open and the calculated reference point will be shown. The permissible limits
(minimum/maximum position) will also be shown. The reference point must be within these limits.
X Check the permissible limits against the value actually measured.
X If necessary, correct the mechanical position of the reference sensor and repeat the measurement
procedure.
X If the value is within the permissible limits, save the data by clicking on
Accept
.
Spare part
Reference point proximity switch for lifting axis
[03047278-01]
Removal/installation
X Loosen the two fastening screws (1) on the
reference sensor.
X Loosen the cable clamps and remove the
cable ties.
X Unthread the connection cable as far as the
control unit back plane and unplug it from the
terminal strip.
X Fit the reference sensor so that the sensor
surface (2) points to the side.
X Align the reference sensor parallel to the right-
hand and top stopper edges (3).
X Restore the electrical connection and fix the
connection cable into place.

Replacing Spare Parts
Limit Switches, Sensors and Light Barriers Replacing the Reference Sensor, Lifting Axis [03047278-xx]
58 Service Manual SIPLACE WPC4
X Perform the necessary calibrations in SITEST,
according to the flow chart. Observe the
correct order.

Replacing Spare Parts
Replacing the Top Lifting Axis Limit Switch [03047279-xx] Limit Switches, Sensors and Light Barriers
Service Manual SIPLACE WPC4
59
3.6.10 Replacing the Top Lifting Axis Limit Switch [03047279-xx]
Settings
X Check the function and correct position of the limit switch. The limit switch must switch when the
lifting axis moves over the switch (end position).
X To do this, open the SITEST main view and select the function=>
SITEST Settings
.
X In the input area
Axis,
select the radio button
Feed axis
.
X In the input area
Travel range
select the button
Limit switch -
.
The lifting axis will be moved so that an actuator on the lifting axis moves over the limit switch. The
limit (end position) will be calculated.
In the SITEST main view, function=>
SITEST inputs/outputs 1,
the display
Top lifting axis limit
switch
will be activated.
A dialog box will open and the calculated value will be shown. The permissible limits (minimum/
maximum position) will also be shown. The end position must be within these limits.
X Check the permissible limits against the value actually measured.
X If necessary, correct the mechanical position of the limit switch and repeat the measurement
procedure.
X If the value is within the permissible limits, save the data by clicking on
Accept
.
X Seal the two mounting bracket fastening screws with locking varnish.
Spare part
Top lifting axis limit switch [03047279-01]
Removal/installation
X Mark the exact position of the limit switch.
X Loosen the two fastening screws (1) on the
limit switch.
X Remove the fixture plate (3).
X Loosen the cable clamps and remove the
cable ties.
X Unthread the connection cable as far as the
control unit back plane and unplug it from the
terminal strip.
X Fit the new limit switch.
X Fit the new limit switch with fixture plate (3) at
the marked installation position.
X Restore the electrical connection and fix the
connection cable into place.