Start position [µm]: Shows the start position for the selected axis.
Target position [µm]: Shows the target position for the selected axis.
Waiting time [ms]: Shows the time which the selected axis should wait in the start or target position
during the continuous run.
Start: Moves the axis in a continuous run between the specified start and target positions.
Cancel: Closes the dialog box without saving any changes made.
Edit...: Opens a dialog box in which the relevant value can be entered for the level.
Setting values
X Mark the line with the parameters which you want to set.
X Select
Edit …
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.

SITEST for WPC4
SITEST Axes Continuous Run
88 Service Manual SIPLACE WPC4
Starting a continuous run
X Select
Start
.
A dialog box shows the date and time at which the continuous run was started. The continuous run
continues until
Cancel
is selected.
Cancel: Terminates the continuous run.

SITEST for WPC4
Feed Axis Positions SITEST Axes
Service Manual SIPLACE WPC4
89
5.7.3 Feed Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Transfer position [µm]: Shows the feed axis transfer position.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the parameter which you want to change.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel