00195346-0302_SM_WPC4_EN - 第90页

SITEST for WPC4 SITEST Axes Lifting Axis Positions 90 Ser vice Manual SIPLACE WPC4 5.7.4 Lif ting Axis Positions  Zero point correct ion [µm]: Shows the reference poin t for calibration of the zero point.  Refill pos i…

100%1 / 108
SITEST for WPC4
Feed Axis Positions SITEST Axes
Service Manual SIPLACE WPC4
89
5.7.3 Feed Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Transfer position [µm]: Shows the feed axis transfer position.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the parameter which you want to change.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
SITEST for WPC4
SITEST Axes Lifting Axis Positions
90 Service Manual SIPLACE WPC4
5.7.4 Lifting Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Refill position [µm]: Shows the position of the lifting axis in which the waffle pack tray carrier can
be removed.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the line with the parameters which you want to edit.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
SITEST for WPC4
Standard Values SITEST Axes
Service Manual SIPLACE WPC4
91
5.7.5 Standard Values
Default speed [0.01 m/s]: Shows the maximum speed of the selected axis.
Default acceleration [0.1 m/s²]: Shows the maximum acceleration with which the feed axis moves
out of the tower.
Default removal speed [0.01 m/s]:Shows the maximum acceleration with which the feed axis
moves into the tower.
OK : Closes the dialog box.
NOTE:
The following parameters are for information purposes only and can not be edited.