00195346-0302_SM_WPC4_EN - 第94页
SITEST for WPC4 SITEST Feed Axis Settings Positioning Data 94 Ser vice Manual SIPLACE WPC4 5.8 SITEST Feed Axis Settings Menu field: Axis, This where you can select the WPC axis to be checke d or set. Feed axis: Perfor…

SITEST for WPC4
Positioning Data SITEST Axes
Service Manual SIPLACE WPC4
93
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
ATTENTION:
WPC machine data is saved directly in the WPC when a change is made.
Back up the current status, so that is can be restored.

SITEST for WPC4
SITEST Feed Axis Settings Positioning Data
94 Service Manual SIPLACE WPC4
5.8 SITEST Feed Axis Settings
Menu field: Axis,
This where you can select the WPC axis to be checked or set.
Feed axis: Performs the selected functions for the feed axis.
Lifting axis: Performs the selected functions for the lifting axis.
Menu field: Functions
Measure transfer position...: Opens a dialog box with a warning.
Zero point correction ..: Opens a dialog box in which the feed axis zero point can be set.
Menu field: Info
Current position: Shows the current position of the activated axis in mm.
Update position: Updates the position shown for the activated axis.
Menu field: Travel range
Reference bero: Moves the selected axis to the reference proximity switch so that the position of
the proximity switch can be redetermined.The position determined is then shown in a dialog box.
Select
OK
to open another dialog box. Select
OK
to start a reference run of the axis.
Limit switch +: Moves the selected axis to the limit switch so that the maximum approach position
can be redetermined. The position determined is then shown in a dialog box. Select
OK
to open
another dialog box. Select
OK
to start a reference run of the axis.
Limit switch -: Moves the selected axis to the limit switch so that the minimum approach position
can be redetermined. The position determined is then shown in a dialog box. Select
OK
to open
another dialog box. Select
OK
to start a reference run of the axis.

SITEST for WPC4
Measuring the Transfer Position SITEST Feed Axis Settings
Service Manual SIPLACE WPC4
95
5.8.1 Measuring the Transfer Position
The feed axis transfer position is automatically measured for the WPC4. This requires that the lifting axis
has been correctly set. You also need a calibration pin. The tower can be completely filled with waffle
pack tray carriers.
X Open the menu Feed Axis, Settings and select
Measure transfer position …
The following message will be shown:
X Insert the calibration pin into the relevant hole at the end of the feed axis and select
OK.
X The feed axis moves to the transfer position, against the calibration pin.
The following message will be shown:"Function is being executed."
X The feed axis performs a reference run.
The following message will be shown: "Reference run is being executed"
X The following message is shown, together with the transfer position value determined:
X Remove the calibration pin.