KE2020-Instruction-Manual-ver1.30.pdf - 第195页

4 – 93 ③ Ve r i f y Using the r adio button, select whether to verify a component : resistor , capacitor and polarity . W hen y ou select “ Capacitor” or “ Resistor”, enter t he upper and lower limits of the ref erence v…

100%1 / 858
4 – 92
When you click the <Set> button, the following “COPLA CHECK DATA” dialog
box appears on the screen.
Check Select whether to perform the coplanarity check or not.
CoplaToleran Set the value used for judgment.
Width Set the width of the electrode. Term Size
Length Set the length of the electrode.
TermCoat Set the lead coating information.
tujou (Normal)
Kotaku-Ari (Glossy)
Kotaku-Nashi (Not glossy)
DarkThreshLvl Set the threshold value for the brightness of a lead.
Power Set the laser strength from 0 to 7.
MeasHeightOffset Set the offset for the measured height.
CoplaOffset Set the offset for the scanned position.
AGCLvl Set the AGC corrected value from 0 to 5.
ScnMode Set the measurement mode:
Auto
HyoujunSokutei-Mode (Normal measurement mode)
Koseido Sokutei-Mode (High-precision measurement mode)
Click the <OK> button to validate your settings, or <CANCEL> button to cancel
your settings.
4 – 93
Verify
Using the radio button, select whether to verify a component: resistor, capacitor
and polarity.
When you select “Capacitor” or “Resistor”, enter the upper and lower limits of the
reference value, unit, tolerable error items.
To specify the unit, click the input area with the right button of a mouse. The
following pop-up menu appears on the screen.
When you check the radio button “Polarity”, you can select the direction by
clicking its input area with the mouse right button.
If the Verify check cannot be performed because another data was changed even
though the item “Check” is set to “Yes”, the following dialog box appears on the
screen.
Dimension check
Using the radio button, select whether to check the dimensions of a component.
When you select “If possible”, the machine checks the dimensions of a
component.
When you select “Yes”, the machine checks the dimensions of a component.
4 – 94
SOT Angle
Check the radio button to decide whether to check the SOT direction.
You can check this radio button only if “SOT” is selected as the component type.
When you check the radio button “Yes”, the system checks the direction of an
SOT component if the divide destination station can check a component.
Note: For a component having leads, be careful to enter the standard size
(“Std.size”). As the component size, specify the length and width (including
the tip of a lead) normally. The standard size to be specified in the “Std. Size”
field of the “Dimension check” section is the horizontal and vertical dimensions