5 − 75 Optional 18.00- mm VCS - Bottom (re flectiv e) light Dimensions of applicable components Division mode Longer side Shorter side Standard 15.50 – 3. 00 mm 15.50 – 3.00 m m 1 × 2 31.00 – 15.51 m m 15. 50 – 3.00 m m …

100%1 / 858
5 74
5.2.5.1 Applicable component dimensions during division recognition
Standard VCS (54.00 mm x 54.00 mm)
- Bottom (reflective) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 50.00 – 3.00 mm 50.00 – 3.00 mm
1 × 2
100.00 – 50.01 mm 3.00 – 50.00 mm
1 × 3
150.00 – 100.01 mm 3.00 – 50.00 mm
2 × 2
75.00 – 50.01 mm 75.00 mm – 50.01 mm
- Back (penetrative) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 50.00 – 9.00 mm 35.00 – 9.00 mm
1 × 2
100.00 – 50.01 mm 35.00 – 17.00 mm
1 × 3
120.00 – 100.01 mm 35.00 – 17.00 mm
Optional 37.00 mm-VCS
- Bottom (reflective) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 34.00 – 3.00 mm 34.00 – 3.00 mm
1 × 2
68.00 – 34.01 mm 34.00 – 3.00 mm
1 × 3
102.00 – 68.01 mm 34.00 – 3.00 mm
2 × 2
68.00 – 34.01 mm 68.00 mm – 34.01 mm
- Back (penetrative) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 34.00 – 9.00 mm 34.00 – 9.00 mm
Optional 27.00-mm VCS
- Bottom (reflective) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 24.00 – 3.00 mm 24.00 – 3.00 mm
1 × 2
48.00 – 24.01 mm 24.00 – 3.00 mm
1 × 3
72.00 – 48.01 mm 24.00 – 3.00 mm
2 × 2
48.00 – 24.01 mm 48.00 mm – 24.01 mm
- Back (penetrative) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 24.00 – 9.00 mm 24.00 – 9.00 mm
5 75
Optional 18.00-mm VCS
- Bottom (reflective) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 15.50 – 3.00 mm 15.50 – 3.00 mm
1 × 2
31.00 – 15.51 mm 15.50 – 3.00 mm
1 × 3
46.50 – 31.51 mm 15.50 – 3.00 mm
2 × 2
31.00 – 15.51 mm 31.00 mm – 15.51 mm
- Back (penetrative) light
Dimensions of applicable components
Division mode Longer side Shorter side
Standard 15.50 – 9.00 mm 15.50 – 9.00 mm
5 76
5.2.6 Light
To change the light data, use the “Light Control” data-editing screen shown in Section
5.2.5 “Ctrl”.
- Split view settings on the “Light Control” screen: The available setting items vary
depending on the value set in the “Split Recognition” fields displayed on the
“Vision Control” screen.
- Light pattern on the “Light Control” screen: The available setting items vary
depending on selection of the “Light type” and Sub type on the “Vision Control”
screen.
When “Back Lights” is selected from the “Light Type” combo box and
“Standard” is selected as the sub type
When “Bottom Lights” is selected from the “Light Type” combo box
* When “EBGA” or “LGA” is
selected as the sub type, the
“Red Side Light 1 and 2” check
boxes are not checked.