00194994_01 - 第41页
SIPLACE Software Guide Version 408.xx 3 Graphical user interface Issue 03/06 EN 3.3 User interface - vie ws and menus 41 Æ Click the Stop proce ssing PCB function in th e Mode menu. The current pla cement operation is ha…

3 Graphical user interface SIPLACE Software Guide Version 408.xx
3.3 User interface - views and menus Issue 03/06 EN
40
WPC refilled 3
As soon as the wafflepack trays which have been identified as being "empty" have been refilled
with components, this must be confirmed, so that the placement head can again access these
trays. This is done using the "WPC refilled" function. 3
Æ Click the WPC refilled button.
This confirms that the wafflepack trays have been refilled.
All the wafflepack trays which have been identified as being "empty" are now regarded as "full".
Placement continues with components from these wafflepack trays.
WPC reference run 3
This function causes the lift of the wafflepack changer to carry out a reference run. 3
NOTE
The wafflepack changer must not be in the refill position when this function is carried out. 3
Æ Click the Stop processing PCB function in the Mode menu.
The current placement operation is halted.
Æ Click the WPC reference run button.
First, any wafflepack tray which has been moved out will be returned to its level. The reference
run is then performed.
Transport position 3
To allow the wafflepack changer to be transported safely, the lift of the waffle pack changer must
be moved to a defined transport position. 3
NOTE
The wafflepack changer must not be in the refill position when this function is carried out. 3

SIPLACE Software Guide Version 408.xx 3 Graphical user interface
Issue 03/06 EN 3.3 User interface - views and menus
41
Æ Click the Stop processing PCB function in the Mode menu.
The current placement operation is halted.
Æ Click the Transport position button.
The lift moves to the defined safety/transport position..
Feed tray 3
This allows you to define the level containing the wafflepack tray to be made available for place-
ment. 3
NOTE
The waffle pack changer must not be in the refill position when this function is carried out. 3
Æ Click the Feed tray button.
The following dialog box is displayed.
3
Æ In the text box, enter the number of the required level and confirm your entry with OK. The waf-
flepack changer moves the wafflepack tray from the selected level to the pick-up position.
NOTE
If a waffle pack tray is already in the pick-up position, it is first moved to its defined level. 3
3
3
3 Graphical user interface SIPLACE Software Guide Version 408.xx
3.3 User interface - views and menus Issue 03/06 EN
42