00197674-01-UM-E-Series-EN-02-2015 - 第161页

User manual SIPLACE E 3 Technical data and assemblies From software version SC 708.0 12/2014 Edition 3.10 Changeover t ab le for SIPLACE E 161 3.10.6 Tape container 3.10.6.1 Description The tape container can hold tape r…

100%1 / 308
3 Technical data and assemblies User manual SIPLACE E
3.10 Changeover table for SIPLACE E From software version SC 708.0 12/2014 Edition
160
3
Fig. 3.10 - 6 Changeover table, front view
(1) Contact for switching the safety switch of the EMERGENCY STOP circuit
(2) Centering pin on the changeover table
(3) Waste tape container
(1)
(2)
(2)
(3)
User manual SIPLACE E 3 Technical data and assemblies
From software version SC 708.0 12/2014 Edition 3.10 Changeover table for SIPLACE E
161
3.10.6 Tape container
3.10.6.1 Description
The tape container can hold tape reels up to 19" (483 mm) in diameter. The insertion of separating
plates is described in section 5.10.4
page 228.
3
Fig. 3.10 - 7 Changeover table, SIPLACE E, with tape container
(1) Tape container with separating plates
(2) Waste tape container
3
PLEASE NOTE
Using spindles
SIPLACE E changeover tables do not generally need spindles.
Use spindles if the error message "Timeout" appears frequently on the SIPLACE
SmartFeeder E.
(1)
(2)
3 Technical data and assemblies User manual SIPLACE E
3.10 Changeover table for SIPLACE E From software version SC 708.0 12/2014 Edition
162
3.10.7 Used tape chute
3
Fig. 3.10 - 8 Used tape chute for the changeover table COT insert
3
3
3.10.8 Empty tape duct on the changeover table COT insert
Item no. 03111421-xx Empty tape duct, 12 mm
Item no. 03111420-xx Empty tape duct, 25 mm
PLEASE NOTE
The used tape chute for the SIPLACE E can only be installed on the changeover table
COT insert for the SIPLACE E (see fig. 5.16 - 3, page 249)
.