7 Maintenance User manual SIPLACE E
7.5 Maintenance on SIPLACE CP12/CP6 From software version SC 708.0 02/2015 Edition
306
7.5 Maintenance on SIPLACE CP12/CP6
7
7.6 Cleaning or Replacing Nozzles
This action is required when encountering a nozzle soil/dirty error.
SIPLACE CP12/CP6l Every 6
months
Every 12
months
Cleaning the Valve Casings
X
Checking, Cleaning and Greasing the Sleeves
X
Cleaning the Turning Station Read Unit
X
Check Cleaning/Greasing Z-Axis
X
Cleaning/Greasing Star Mount
X
Check Cleaning/Greasing Vacuum Distributor
X
Check/Cleaning/Greasing Star brake
X
Check/Cleaning/Greasing Z-axis Valve adjustment drives
X
Check/Cleaning Turning station
X
Check/Cleaning Vacuum generator
X
www.e-by-siplace.com
Item no.:00197674-01 ASM Assembly Systems Singapore Pte ltd
2 Corporation Road
#01-03 Corporation Place
Singapore 618494