00195722-0102_UM_X-Serie_SR605_EN - 第220页

3 Technical data for the machine User Manual SIPLACE X-Series 3.11 SIPLACE X-series component trolley From software version SR.605.xx 07/2008 EN Edition 220 3 Fig. 3.1 1 - 7 Component table, SIPLACE X-series, front view …

100%1 / 494
User Manual SIPLACE X-Series 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.11 SIPLACE X-series component trolley
219
3.11.6 SIPLACE X-series component table
The front slider guides of the feeder modules are placed on the insertion aid (item 1 in Fig.
3.11 - 6
). As it is pushed in, the guides of the feeder module (item 12 and 13 in Fig. 3.9 - 2, page
167
) slide on the guide profile (item 2 in Fig. 3.11 - 6) as far as the stop bar (item 4 in Fig. 3.11 -
6). A centering hole (item 5 in Fig. 3.11 - 6, page ) on the stop bar holds the "front" centering pin
(item 4 in Fig. 3.9 - 1
, page 166) of the X feeder module. At the same time, the locking latch (item
1 in Fig. 3.11 - 7
, page 220) of the component table latches on the locking roller (item 1 in Fig. 3.9
- 1, page 166) of the feeder module. The "back" centering pin (item 12 in Fig. 3.9 - 1, page 166)
on the top of the feeder module is held by the recess in the centering bar (item 3 in Fig. 3.11 - 6
).
3
Fig. 3.11 - 6 Component table, SIPLACE X-series, back view
(1) Insertion aid
(2) Guide profile (Ω profile)
(3) Centering bar for holding the "back" centering pin for X feeder modules
(4) Stop bar
(5) Centering holes
(6) Contact for switching the safety switch of the EMERGENCY STOP circuit
(7) Hand guard
3 Technical data for the machine User Manual SIPLACE X-Series
3.11 SIPLACE X-series component trolley From software version SR.605.xx 07/2008 EN Edition
220
3
Fig. 3.11 - 7 Component table, SIPLACE X-series, front view
(1) Locking latches
(2) Centering pin on the component table
(3) Compressed air coupling
(4) Grounding pin
(5) Centering hole on the component table
User Manual SIPLACE X-Series 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.11 SIPLACE X-series component trolley
221
3.11.7 Support for an additional tape reel (X-series)
3
Fig. 3.11 - 8 Support for an additional tape reel (X-series)
(1) Support for an additional tape reel, item no. 00141217-xx
(2) Mounting device for the support
X-series feeder modules can process component tapes without problems if the lateral offset be-
tween the feeder module and the tape reel does not exceed 60 mm. If a predefined set-up means
that the maximum permitted offset cannot be maintained, we recommend that you use the mount
for an additional tape reel (item 1). Simply insert the mount into the holder (item 2) and push it until
the offset is less than the maximum permitted value of 60 mm. The component trolley has 5 hold-
ers in total. Each tape reel mount can hold 2 tape reels, which means that up to ten 15" (381 mm)
reels can be positioned above the tape container.
max. 60 mm