00195722-0102_UM_X-Serie_SR605_EN - 第267页

User Manual SIPLACE X-Series 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine 267 4.3.7.2 Assembly 4 Fig. 4.3 - 8 Fitting the extension kit on the PCB…

100%1 / 494
4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
266
Remove the cable covers (items 3 and 5 in Fig. 4.3 - 7, page 265) from the rails (item 1 in Fig.
4.3 - 7
, page 265) of the output conveyor.
Carefully place the rail (item 1 in Fig. 4.3 - 7
, page 265) against the rail on the processing
conveyor (item 2 in Fig. 4.3 - 7
, page 265).
CAUTION 4
Be careful not to cut through any of the light barrier or drive motor cables.
Fix each rail using 4 fillister head screws M6x16 and the associated washers (item 7 in Fig.
4.3 - 7
, page 265).
Connect the power cable to the light barriers and drive motors.
Fix the cable covers in place (item 3 and 5 in Fig. 4.3 - 7
, page 265).
Introduce the hexagonal shaft (item 9 in Fig. 4.3 - 7
, page 265) into the drive unit (item 10 in
Fig. 4.3 - 7
, page 265).
Make sure that the hexagonal shaft guide (item 8 in Fig. 4.3 - 7
, page 265) always points to-
wards the conveyor side wall to which the drive unit (item 10 in Fig. 4.3 - 7
, page 265) is fixed.
4.3.7 Fitting the extension kit on the PCB output side
4.3.7.1 Tools
Allen keys, DIN 911, set
Machine key
User Manual SIPLACE X-Series 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine
267
4.3.7.2 Assembly
4
Fig. 4.3 - 8 Fitting the extension kit on the PCB output side
(1) Extension kit
(2) Door
(3) Fillister head screw DIN 912, M6x16 and washer
(4) Ground connection point
(5) Conveyor cover
(6) Side panel, detached
(7) Drawer unit rail
(8) Axis unit, gantries 1 and 3 (X2), axis unit, gantry 3 (X3) or axis unit, gantries 2 and 3 (X4)
4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
268
Release the two horizontal tensioners (item 6 in Fig. 4.3 - 8, page 267).
CAUTION 4
Do not unscrew the three bottom screws straight away. Simply loosen them so that the side
plate does not fall off.
Detach the ground cable from the side plate.
Remove both doors (item 2 in Fig. 4.3 - 8
, page 267) from the extension kit (item 1).
PLEASE NOTE: 4
To avoid damage, we recommend that a second person helps to assemble the extension kit.
Set down the axis unit (item 8 in Fig. 4.3 - 8
, page 267) at the side of the machine in order to
make enough space to fit the extension kit (item 1 in Fig. 4.3 - 8
, page 267).
Make sure that the connecting cables to the axis unit are not too tight.
Lift the extension kit (item 1 in Fig. 4.3 - 8
, page 267) against the machine frame and position
it so that the assembly bracket lies on the assembly bar (item 7 in Fig. 4.3 - 8
, page 267).
CAUTION 4
Make sure that the extension kit does not collide with the hexagonal shaft of the PCB con-
veyor and the hexagonal shaft becomes bent.
Fix the extension kit using 4 fillister head screws M6x16 and the associated washers (item 3
in Fig. 4.3 - 8
, page 267).