00195722-0102_UM_X-Serie_SR605_EN - 第271页
User Manual SIPLACE X-Series 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine 271 4.3.7.7 Fitting the "bottom" hand guard The machines are s…

4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
270
4.3.7.5 Fitting the grounding cable for the doors
→ Fix the two grounding cables for the doors (item 4 in Fig. 4.3 - 8, page 267) to the machine
frame as follows:
4
Fig. 4.3 - 9 Fitting the grounding cable
4
4
4
4
4
4.3.7.6 Checking and setting the protective cover switch
→ Check that the protective cover switch (item 2 in Fig. 4.3 - 17, page 286) is working correctly.
→ Adjust the protective cover switch if necessary (see service manual).
Hex nut M5
Spring washer M5, DIN 7980
Washer M5, DIN 125
Cable lug, annular
Contact washer

User Manual SIPLACE X-Series 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine
271
4.3.7.7 Fitting the "bottom" hand guard
The machines are supplied with just one "bottom" hand guard. If the machines are installed within
a line, then no hand guard is required between immediately adjacent output and input conveyors.
WARNING 4
Always fit the "bottom" hand guard (item no. 03045426-xx) on the input side of the first place-
ment machine and on the output side of the last placement machine of a line using 4 hexagon
socket head screws M4x12. This will prevent your personnel reaching into the machine without
authorization.
4
Fig. 4.3 - 10 Fitting the "bottom" hand guard on the PCB output side
(1) "Bottom" hand guard, item no. 03045426-xx
(2) Protective cover switch

4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
272
4.3.8 Installing the axis unit
4.3.8.1 Axis unit X2 (gantry 1 and gantry 3) - electrical connection points
4
Fig. 4.3 - 11 Axis unit X2 (gantry 1 and gantry 3), rear panel - electrical connection points
Plug
Plug
Plug