00195722-0102_UM_X-Serie_SR605_EN - 第317页

User Manual SIPLACE X-Series 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.6 Adapting th e used tape channel 317 4 Fig. 4.6 - 2 Used tape channel with component reject bin (1) Separa…

100%1 / 494
4 Setting up and commissioning User Manual SIPLACE X-Series
4.6 Adapting the used tape channel From software version SR.605.xx 07/2008 EN Edition
316
4.6.1.1 Safety instructions
WARNING 4
Switch the placement machine off at the main switch to remove the dividing plate.
Disconnect the machine from the power and compressed air supply.
Secure the machine to prevent it being switched on again, as described in Section 2.10
, page
96
.
Wait until the operating pressure for the tape cutter has dropped to 0 MPa.
Do not reach inside the used tape channel.
4.6.1.2 Removing the separating plate
Loosen the two hexagon head screws (item 2 in Fig. 4.6 - 1, page 315).
Pull out the separating plate (item 1 in Fig. 4.6 - 1
, page 315).
4.6.2 Adapting the SIPLACE HF used tape channel to the component height
If S feeder modules that process component tapes with a pocket height > 17 mm are used, such
as, for example, the 44 mm S DP feeder module, then the separating plate (item 1 in Fig. 4.6 - 2
,
page 317
) must be removed.
4.6.2.1 Safety instructions
WARNING 4
Switch the placement machine off at the main switch to remove the dividing plate.
Disconnect the machine from the power and compressed air supply.
Secure the machine to prevent it being switched on again, as described in Section 2.10
, page
96
.
Wait until the operating pressure for the tape cutter has dropped to 0 MPa.
Wear robust protective gloves.
Do not reach inside the used tape channel.
User Manual SIPLACE X-Series 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.6 Adapting the used tape channel
317
4
Fig. 4.6 - 2 Used tape channel with component reject bin
(1) Separating plate for tapes > 17 mm, removable
(2) DIN 84 - M3x6 screw, 2x
4
4
4.6.2.2 Removing the separating plate
Loosen the two slotted screws (item 2 in Fig. 4.6 - 2).
Pull out the separating plate (item 1 in Fig. 4.6 - 2
).
4 Setting up and commissioning User Manual SIPLACE X-Series
4.7 Commissioning the machine From software version SR.605.xx 07/2008 EN Edition
318
4.7 Commissioning the machine
4.7.1 Commissioning the machine at the customer's premises
Check all modules for correct seating.
Wipe off the linear guide rails with a lint-free cloth before removing the shipping braces for the
X/Y axis. Do not use any solvent to do this (see Section 4.3.19
, page 307.
Switch on the machine and perform a reference run.
Copy the placement program onto the computer and test it.
Check the machine zero point after a period of warming up of 3 - 4 h.
Get the customer's operating personnel to equip the feeder modules according to the cus-
tomer's placement program.
Instruct them in handling the feeder modules using the JobGuide.
Check all customer-specific installed options (in particular software) for good functioning and
order any necessary spare parts using the order form or by fax.
4.7.2 Instructing the customer's personnel
Explain all customer-specific installed options, in particular software / software compatibility.
Explain programming of the program editors on the line computer / SIPLACE Pro.
Instruct the operators and line engineers in using the station software.
Explain about password protection.
Instruct the customer's personnel according to the user manual and the preventive mainte-
nance.
4.7.3 A test run or starting production
Test the line using the test PCB or a PCB provided by the customer.
Record the customer product and performance data, prepare the data and document the data
in the installation report.
Secure the data and give the customer security copies.