00193922-03 - 第197页

User manual SIPLAC E HF series 4 Setting up and commissioning Software Vers ion SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine 197 4.4.8.4 HF/3 axis unit (gant ry 3) - Connecting the plugs Æ Co nnect t…

100%1 / 374
4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
196
4.4.8.3 HF/3 axis unit (gantry 3) - Electrical connection points
4
Fig. 4.4 - 13 HF/3 axis unit (gantry 3), back panel - Electrical connection points
User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
197
4.4.8.4 HF/3 axis unit (gantry 3) - Connecting the plugs
Æ Connect the power cable as shown in the following diagram:
4
4
4
Æ Check the switch settings for S1
1: ON
2: ON
Æ Continue from section 4.4.8.5 "Fitting the axis unit", page 198.
HF/3 axis unit
(gantry 3)
Plug
Connecting cable
NOTE
Plug Cable
X21 X21
03009782
03009783
03009784
03009785
03009786 W1-W5
Secure connector with clips
X22 X22
03009802
03009803
03009804
03009805
03009807
Secure connector with clips
X4ur X4ur 03009800 Snap connector into place
X4ut X4ut 03009801 Snap connector into place
X1uo
X3uo
X5uo
X1uo
X3uo
X5uo
03009811
03009812
03009813
Insert as far as the stop
X1up
X3up
X5up
X1up
X3up
X5up
03009814
03009815
03009816
Insert as far as the stop
X30_1sq
X30_2sq
X30_1sq
X30_2sq
03010054
03010054
Screw tightly
4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
198
4.4.8.5 Fitting the axis unit
Æ Carefully lift the axis unit onto the rail in the extension kit.
Æ Make sure that you do not squash any cables.
Æ Push the axis unit into the extension kit as far as the stop.
Æ Secure the axis unit with the fillister head screw.
Æ Insert the cover.
Æ Fix the grounding cable to the doors (item 2 in Fig. 4.4 - 8, page 188), as shown in Fig.
4.4 - 10
on page 192.
Æ Lock the doors.
4.4.8.6 Fitting the side plates
Æ Fix the grounding cable to each side plate (item 6 in Fig. 4.4 - 8, page 188), as shown in Fig.
4.4 - 10
page 192.
Æ Fix the side plate to the machine frame with 6 fillister head screws.
PLEASE NOTE
If you have dismantled the output conveyor, continue from section 4.4.9
" Fitting the input con-
veyor" on page 199.
Once the input conveyor is fitted, then continue the assembly work from section 4.4.13
"Fitting
the main fault indicator" on page 214.