4 Setting up and commissioning User manual SIPLACE HF series 4.4 Setting up the placement machine Software Version SR.50x .xx 01/2006 US Edition 210 4.4.1 1.3 HF/3 computer unit - Connecting the pl ugs Æ Connect th e pow…

100%1 / 374
User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
209
4.4.11.2 HF computer unit - Connecting the plugs
Æ Connect the power cable as shown in the following diagram:
4
4
4
Computer unit,
front panel
(Fig. 4.4 - 19)
Plug
Connecting cable
NOTEPlug Cable
X5pc X5pc 03002958 + 03002559 Insert as far as the stop
X7pc X7pc 03002967 Secure with screws
X8pc X8pc 03002970 Secure with screws
X6pn X6pn 03010051 Secure with screws
X11pn X11pn 03010059 Secure with screws
X6pt X6pt 03002507 W1+W2 Secure with screws
X7pt X7pt 03003438 W1+W2 Secure with screws
X6pu X6pu 03002508 W1+W2 Secure with screws
X7pu X7pu 03003435 W1+W2 Secure with screws
Computer unit,
back panel
(Fig. 4.4 - 20
)
Plug
Connecting cable
NOTEPlug Cable
X15pz X15pz 03003434 Fix with screws
X3pz X3pz 03004063 Fix with screws
PE1 Cable ring Grounding cable
Fix as shown in Fig. 4.4 - 17
,
page 205
X27pz X27pz 03003437 W1-W2 Insert as far as the stop
X2pz X2pz 03002966 W1-W5 Fix with screws
X1pz X1pz 03002969 W1-W5 Fix with screws
X62pz X62pz 03002488 Snap into place
PE2 Cable lug Grounding cable Insert as far as the stop
P24 / GND X1 Fan in extension kit Insert as far as the stop
4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
210
4.4.11.3 HF/3 computer unit - Connecting the plugs
Æ Connect the power cable as shown in the following diagram:
4
4
4
Computer unit,
front panel
(Fig. 4.4 - 19)
Plug
Connecting cable
NOTEPlug Cable
X5pc X5pc 03002958 + 03002559 Insert as far as the stop
X7pc X7pc 03002967 Secure with screws
X8pc X8pc 03002970 Secure with screws
X6pn X6pn 03010051 Secure with screws
X11pn X11pn 03010059 Secure with screws
X6pt X6pt 03010607 W1+W2 Secure with screws
X7pt X7pt 03010608 W1+W2 Secure with screws
X6pu X6pu 03002508 W1+W2 Secure with screws
X7pu X7pu 03003435 W1+W2 Secure with screws
Computer unit,
back panel
(Fig. 4.4 - 20
)
Plug
Connecting cable
NOTEPlug Cable
X15pz X15pz 03003434 Fix with screws
X3pz X3pz 03004063 Fix with screws
PE1 Cable ring Grounding cable
Fix as shown in Fig. 4.4 - 17
,
page 205
X27pz X27pz 03003437 W1-W2 Insert as far as the stop
X2pz X2pz 03002966 W1-W5 Fix with screws
X1pz X1pz 03002969 W1-W5 Fix with screws
X62pz X62pz 03002488 Snap into place
PE2 Cable lug Grounding cable Insert as far as the stop
P24 / GND X1 Fan in extension kit Insert as far as the stop
User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
211
4.4.11.4 Fitting the computer unit
Æ Plug in the plug-in connectors on the back panel of the computer unit (see section 4.4.11.2,
4.4.11.3
).
Æ Carefully lift the computer unit onto the rail in the extension kit.
Æ Make sure that you do not squash any cables.
Æ Check that the cables for the front panel are in the lateral cable routing plate
(item 1 in Fig. 4.4 - 19
, page 207).
Æ Fix the cables to the front panel with cable ties.
Æ Push the computer unit into the extension kit as far as the stop.
Æ Connect the fan cable to the computer unit cable.
Æ Plug in the plug-in connectors on the front panel of the computer unit (see section 4.4.11.2,
4.4.11.3
).
Æ Secure the computer unit with the fillister head screw.
Æ Fix the grounding cable to the doors (item 2 in Fig. 4.4 - 15, page 201), as shown in Fig.
4.4 - 17
on page 205.
Æ Lock the doors.
PLEASE NOTE
On HF placement machines, continue from section 4.4.11.5
"Fitting the side plates".
On HF/3 placement machines, continue from section 4.4.12
"Installing the axis unit on the HF/3
(gantry 1 and gantry 4)" on page 212.
4.4.11.5 Fitting the side plates
Æ Fix the grounding cable to each side plate (item 5 in Fig. 4.4 - 15), as shown in Fig. 4.4 - 17
page 205
.
Æ Fix the side plate to the machine frame with 6 fillister head screws.
Æ Continue from section 4.4.13 "Fitting the main fault indicator", page 214.