X7056_Operating manual_en.pdf - 第125页

Software Automatic mode 125 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a Test history In the field T EST H ISTORY , the last 50 inspected PCBs are displayed in chronological…

100%1 / 280
Software
Automatic mode
124
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Overview
File tabDEFECT STATISTIC
Description of the fields
No. Name Description
1 TEST HISTORY Displays the last 50 inspected PCBs
(can be configured). See „Test history“
(Page 125)
2 INSPECTION DETAILS Displays the details for the inspection
history selected in the field "Test
history". See „Inspection details“
(Page 126)
3 SERIAL DEFECT This field is first available as of soft-
ware version 7.38. See „Serial defect“
(Page 126)
4 DEFECT DISTRIBUTION Displays the entire PCB, all compo-
nents, the cameras and the defect
frequency. See „Defect distribution“
(Page 127)
5 PARETO DISPLAY Displays a configurable Top Ten
Statistic. See „Pareto display“ (Page
128)
134
5
2
Software
Automatic mode
125
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Test history
In the field TEST HISTORY, the last 50 inspected PCBs are displayed
in chronological order.
Field TEST HISTORY
Description of the field test history
No. Name Value Description
1 BARCODE - Displays the barcode of the PCB.
2 INSPECTION TIME - Displays the time the PCB was
inspected.
3 INSPECTION PLAN - Displays the inspection plan
names.
4 INSPECTION DURA-
TION
- Displays the analysis time
required.
5 SINGLE PANEL - Displays how many single panels
have defects.
6 COMPONENTS - Displays how many components
were inspected with defects.
7 WINDOW -
8 Inspection status Displays the result of the inspection.
PCB with defects.
PCB without defects.
Inspection aborted by user or
inspection system.
8
1 2 3 4 5 6 7
Software
Automatic mode
126
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Inspection
details
When one of the inspections in the field TEST HISTORY are chosen,
its details are displayed:
FieldINSPECTION DETAILS
Serial defect
The field SERIAL DEFECT is first available as of Version 7.38.
Description of the field "Inspection Details"
No. Name Description
1 AOI RESULT Displays the result from the inspection
system.
2 IDENTIFICATION Displays the ID of the corresponding
component.
3 PATTERN Displays the name of the component
type.
4 CODE Displays the component article
number.
5 ANALYSIS Displays the analysis process being
used.
6 WINDOW Displays the window number.
1 2 3 4 5 6