Operation
Operating the safety features
149
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Operating the safety features
This section explains the inspection system's safety features.
The following safety features are described:
STOP mode (Page 149)
EMERGENCY STOP (Page 150)
Releasing the PCB clamping of the AXI transport track (Page
152)
Protective barrier safety features (Page 153)
STOP mode
The STOP mode switches off the current to the system drive
elements; some system components still carry current. These
components are indicated by safety and warning labels.
The following themes are presented:
Actuating the STOP mode
Ending the STOP mode
Actuating the
STOP mode
To allow safe access into the inspection system for setup, mainte-
nance, or troubleshooting, actuate the STOP mode.
The STOP mode is actuated when
the front lift door
or the front door
or the rear swing doors are opened
This deactivates all hazardous movements of the axes and the
transport system and switches off the X-ray tube. The system
computers remain ready for operation.
Release the PCB clamping manually, see „Releasing the PCB
clamping of the AXI transport track“ (Page 152).
The following message is displayed:
STOP message
Operation
Operating the safety features
150
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Ending the
STOP mode
Perform the following work steps:
1. Close all the doors.
2. Press the ON button.
3. Choose the R
ESTART button on the STOP notice.
The axes initialize.
The inspection system is ready to operate.
4. Start the Viscom software, see „Starting the Viscom software“
(Page 155).
The AOI software starts.
The AXI software starts.
The STOP mode is ended.
EMERGENCY STOP
The EMERGENCY STOP button may only be actuated in emergen-
cies. A protective shroud around the button ensures that it is not
accidentally actuated.
The following themes are presented:
EMERGENCY STOP button
Actuating EMERGENCY STOP
Cancelling EMERGENCY STOP
EMERGENCY
STOP button
The EMERGENCY STOP button switches off all energies and poten-
tial risks in the system. The UPS maintains a power supply of 230
V to the system computer, take appropriate measures.
EMERGENCY STOP button
Operation
Operating the safety features
151
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Actuating
EMERGENCY
STOP
Perform the following work steps:
Press the EMERGENCY STOP button.
The power to the inspection system is switched off.
The monitor is switched off.
the UPS ensures the regulated shutdown of the system
computer.
Release the PCB clamping manually, see „Releasing the PCB
clamping of the AXI transport track“ (Page 152).
EMERGENCY STOP has been actuated.
Cancelling
EMERGENCY
STOP
Perform the following work steps:
1. Turn the EMERGENCY STOP button clockwise to unlock it.
2. Turn on the UPS devices.
The axes initialize.
The inspection system is ready to operate.
3. Start the Viscom software, see „Starting the Viscom software“
(Page 155).
The AOI software starts.
The AXI software starts.
EMERGENCY STOP has been cancelled.
Releasing the PCB Clamping
To remove a PCB from the AOI or AXI transport during STOP or
EMERGENCY STOP states, release the PCB clamping manually.
The work steps in detail:
Releasing the PCB clamping of the AOI transport track
Releasing the PCB clamping of the AXI transport track
Releasing the
PCB clamping
of the AOI
transport
track
Precondition:
The STOP mode is actuated.