Malfunctions
Troubleshooting
163
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Troubleshooting
The section on troubleshooting provides guidance for problems
with the inspection system.
The following malfunction areas are covered:
Hardware (Page 164)
Software (Page 164)
PCB transport (Page 165)
Description of the malfunctions table
Malfunctions are listed in a table containing the following columns:
Problem/Message: contains the problem description.
Diagnosis: contains possible causes of the malfunction, which
should be treated in the order they are given.
Countermeasure: contains instructions for solving the malfunc-
tion.
If the malfunction cannot be resolved after all the countermea-
sures are carried out, notify the person responsible for the system
and if necessary, the Viscom AG also, see „Customer Support“
(Page 167).

Malfunctions
Troubleshooting
164
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Hardware
In the following table, hardware malfunctions are listed.
Software
In the following table, software malfunctions are listed.
Hardware malfunctions
Problem/messag
e
Diagnosis Countermeasure
Inspection
system does not
start.
Have an electrician
check the mains
current and system
connection.
Perform these steps:
1 Check the fuses of the
operation building
2 Connect the inspection
system to the mains
current, see „Installation“ >
„Providing a standard
connection“ (Page 78).
Axes are not activated
(ON button does not
light).
Perform these steps:
1 Close all the doors.
2 Press the ON button.
The system computer
doesn't start.
Switch on the UPS.
The monitor screen
stays black.
Perform these steps:
1 Switch on the monitor.
2 Check the monitor cable.
Message Switch
on system, check
air supply
The white ON button
doesn't light up.
Perform these steps:
1 Close all the doors.
2 Press the ON button.
3 Confirm the message on
the monitor.
Software malfunctions
Problem/messag
e
Diagnosis Countermeasure
No data is
displayed at the
verification
station.
The barcode scanner is
not switched on.
Switch on the barcode
scanner.
Wrong barcode. Enter the correct barcode.
The network connection is
interrupted.
Restore the network
connection.

Malfunctions
Troubleshooting
165
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
PCB transport
In the following table, PCB transport malfunctions are listed.
PCB transport malfunctions
Problem/messag
e
Diagnosis Countermeasure
PCBs are not
infed.
PCB is stuck inside. Perform these steps:
1 Actuate the STOP mode.
2 Remove the PCB from the
transport, see „Releasing
the PCB clamping of the
AXI transport track“
(Page 152).
3 If necessary, adjust the
transport width, see
„Installation“ > „Adjusting
the transport track width“
(Page 86).
PCB is not transferred
from external transport
conveyor.
Check the external conveyor
and switch it on.
Barcode is not read. Perform these steps:
1 Check the power supply to
the scanner.
2 Check the position of the
PCB in the transport
system.
3 Check the PCB barcode.
Check the
SMEMA/SV70.
Connect the SMEMA/SV70,
see „Installation“ >
„Connecting SMEMA/SV70“
(Page 89).
PCBs are not
outfed.
PCB is stuck inside. Perform these steps:
1 Actuate the STOP mode.
2 Remove the PCB from the
transport, see „Releasing
the PCB clamping of the
AXI transport track“
(Page 152).
3 If necessary, adjust the
transport width, see
„Installation“ > „Adjusting
the transport track width“
(Page 86).
PCB is not accepted by
external transport
conveyor.
Perform these steps:
1 Check the external
conveyor and switch it on.
2 If necessary, adjust the
transport width, see
„Installation“ > „Adjusting
the transport track width“
(Page 86).