X7056_Operating manual_en.pdf - 第177页

Maintenanc e Lubricating the runner blocks - AOI 177 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a Lubricating the runner blocks - AOI To ensure smooth functioning of the tra…

100%1 / 280
Maintenance
Maintenance schedule
176
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Yearly maintenance
Component Measures Time
required
System Perform these steps:
Check cables in all the cable
guides for abrasion, correct
positioning and placement;
replace if necessary.
Check the signal lamp func-
tion.
approx. 15-
30 min.
Transport system Check the light barriers /
sensors and end switch.
Approx.
10 min.
Positioning unit Check magnets for damage. approx. 10
min.
3 yearly maintenance
Component Measures Time
required
System + external
components
Perform these steps:
Check all screws and lacquer
if required.
Check all control modules;
clean outside, inside if neces--
sary.
approx. 10
min.
X-ray tube Replace the battery, see
„Exchanging the battery“ (Page
220). After re-installing the X-
ray tube carry out a geometric
calibration.
approx. 15
min.
Approx. 6 hr.
X-ray tube Check whether the sealed tube
should be reconditioned, see
„Reconditioning of sealed X-ray
tube“ (Page 222)
approx. 8 hr.
Maintenance
Lubricating the runner blocks - AOI
177
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Lubricating the runner blocks - AOI
To ensure smooth functioning of the transport system, the posi-
tioning units and the width adjustment, grease the guide carriages
regularly.
The following sections describe how to lubricate the runner blocks:
Transport system AOI
Lubricating the AOI runner blocks
Transport system AOI
The following illustration indicates the position of the runner blocks
to be lubricated in the AOI transport section of the inspection
system:
AOI runner block
Grease the runner blocks in the AOI section through the 6M funnel
grease nipples.
Legend
Name Size Numbe
r
Grease in cm
3
Rexroth standard runner block
R1622 (steel)
25 8 1.4
Y
X
Maintenance
Lubricating the runner blocks - AOI
178
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Rexroth R1622 runner block with funnel grease nipple
Lubricating the AOI runner blocks
Required: Lubricating grease KP2K, NLGI class 2 according to DIN 51818
Grease gun
Lubricating the
X-axis runner
block
WARNING
Hazard of injury
Turn off the system and secure it against accidental restart
before starting lubrication.
Perform the following work steps:
1. Stand in front of the inspection system and open the front lift
door.
2. Check guide carriage and guide rails for contamination; clean if
required.
3. Grease the four X-axis guide carriages from above through the
PCB support. Open access to the AOI transport track to reach
the four lube nipples on the PCB support with the grease gun.
Funnel grease
nipple 6M