X7056_Operating manual_en.pdf - 第184页
Maintena nce Lubricating the runner blocks - AXI 184 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a 3. Grease the two rear guide carriages (left) and the right guide carriage …

Maintenance
Lubricating the runner blocks - AXI
183
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
6. Grease runner block D through the angled grease nipple; use
0.4 cm
3
grease.
7. Manually move the AXI transport track into the AOI section so
that it is adjacent the AOI transport track.
8. Stand in front of the inspection system.
The two runner blocks on the AXI transport tracks can now be
reached.
9. Grease the runner blocks through the funnel grease nipples;
use 0.4 cm
3
grease.
10.Move the runner blocks back and forth with three double
strokes; the distance should be equal to at least three times
the length of a runner block.
11.Check if there is a visible grease layer on the guide rails.
Completed, continue...
Lubricating the
Y-axis runner
blocks
Perform the following work steps:
1. Move the AXI transport track in y direction as much as possible
into the AXI area.
2. Stand behind the inspection system.

Maintenance
Lubricating the runner blocks - AXI
184
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
3. Grease the two rear guide carriages (left) and the right guide
carriage on the Y-axis through the funnel grease nipples; use 3
cm
3
or 3 cm
3
grease.
4. Manually move the AXI transport track into the AOI section so
that it is adjacent the AOI transport track.
5. Stand in front of the inspection system.
6. Grease the two front runner blocks through the funnel grease
nipples; use 1.4 cm
3
grease.

Maintenance
Lubricating the runner blocks - AXI
185
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
7. Grease the two middle runner blocks through the funnel-type
lube nipples, which are located beneath the two front runner
blocks.
8. Move the runner blocks back and forth with three double
strokes; the distance should be equal to at least three times
the length of a runner block.
9. Check if there is a visible grease layer on the guide rails.
The Y-axis guide carriages are greased.
The guide carriages in the AXI section are greased.