Reconditioning of sealed X-ray tube
Viscom and the manufacturer of the sealed tube offer a recondi-
tioning of the tube within the first 3 years as of delivery date.
Reconditioning includes exchanging the vacuum piston of the tube.
The vacuum piston restricts the life span of the tube since cathode,
vacuum and anode of the tube deteriorate during operation.
Because the reconditioning of the system's tube at the manufac-
turer's takes too long, Viscom offers an exchange for one that has
already been reconditioned. The warranty period of the recondi-
tioned tube is 18 months.
The exchange of the tube takes approx. 8 working hours.
Please consider, that the reconditioning or exchange with a recon-
ditioned tube is only possible within the first 3 years as of delivery
date!
Maintenance
Exchanging filter mat on AOI system computer
223
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Exchanging filter mat on AOI system
computer
In the ventilators on the system computer, there are filter mats to
filter the air that comes into the system computer. These filter
mats must be exchanged yearly; if there is heavy contamination,
every three months.
Required: Cross-tip screwdriver
Allen (hex) key 3 mm
Filter mat
Perform the following work steps:
1. Open the front lift door of the inspection system.
You have free access to the system computer.
2. Remove system computer; if necessary, detach cable.
The rear side of the system computer is open.
3. Loosen the knurled screws of the ventilator housing and
remove them.
4. Remove the 4 screws from the rear side of the housing.
Maintenance
Exchanging filter mat on AOI system computer
224
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
5. Take out the filter mat and evaluate it:
For minimal contamination, blow out filter mat with
compressed air.
For heavier contamination and yearly, exchange filter mat.
6. Reinstall filter mat.
7. Reinstall system computer and connect cable according to
circuit diagram.
Filter mat on AOI system computer is exchanged.