Packing
Packing the inspection system
248
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
6. Affix the transport indicators, see „Transport indicators“ (Page
59).
7. Completely wrap the system with two layers of stretch wrap.
The inspection system is wrapped airtight.
Completed. The inspection system is wrapped.
Packing the inspection system in the transport case
For overseas transport, Viscom recommends having the inspection
system packed in a suitable transport case by an industrial packing
company.
NOTE
To prevent improper lifting and transporting, mark the center of
gravity on the transport case according to the center of gravity
sketches, see „Center of Mass“ (Page 260).
Transporting the inspection system
Before beginning to transport the system, read and understand the
accompanying transport manual.
Packing
Storage
249
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Storage
For storage, it is important to ensure that the inspection system
and its accessories are protected from potential damage.
NOTE
Always store the system in its original packaging until it is installed
and observe the storage requirements.
Ensure appropriate protection to prevent damage due to the
following factors:
Rain, humidity
Temperature fluctuations that may cause condensation
Dust
Aggressive and soiling environments which may lead to corro-
sion
Mechanical damage or unauthorized opening of the packaging
Strong vibration (loosening of attached parts, fatigue damage,
etc.)
If the X-ray tube is not used for a longer time, a warmup
procedure has to be performed at least every 3 months to
guarantee function, see „Maintenance“ > „Warm-up procedure“
(Page 220).
Storage conditions
Permissible weight load for the
ground surface
950kg/m
2
Permissible weight load for the
ground surface (per system foot)
39 N/cm
2
Ambient temperature 0°C to 70°C
Humidity to 80%, not condensed
Average humidity <60 %
Packing
Disposal
250
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Disposal
Disposal of the inspection system must be done according to the
regulations of the land the system is installed in.
Beryllium waste (sealed X-ray tube) must be disposed off as
hazardous waste in special and sealed containers.
It is possible to allow the Viscom AG to properly dispose of the
system. The customer bears the cost of transporting the system to
Viscom.
The Viscom AG observes the regulations established by RoHS-
Directive 2002/95/EC.