X7056_Operating manual_en.pdf - 第252页

Technical sp ecifications System specificat ions 252 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a System specifications This section provides general techni cal information …

100%1 / 280
Technical specifications 251
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Technical specifications
This chapter provides all the important technical data for the
inspection system.
It contains the following technical specifications:
System specifications (Page 252)
Environmental conditions (Page 253)
XM camera technology (Page 254)
Sealed X-ray tube (Page 255)
Flat panel detector (Page 256)
Transport system (Page 257)
System Dimensions (Page 258)
Center of Mass (Page 260)
Tipping Angle (Page 261)
System weight (Page 263)
Technical specifications
System specifications
252
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
System specifications
This section provides general technical information of the inspec-
tion system.
The following data are presented:
Electrical specifications (Page 252)
Communication interfaces (Page 252)
Noise emission (Page 252)
System computer (Page 252)
Electrical specifications
Communication interfaces
Noise emission
The noise level of the inspection system is under 70 db.
System computer
Electrical specifications
Power supply 230/400 VAC, 50/60 Hz, 3 phase, N, PE
Power supply with internal
transformer for main power
adaptation
190 V - 600 VAC, 50/60 Hz, 3 P/N/PE
Average power consumption 0.78 kW/h
Max. Power 1.5 kW
Min. Power 0.62 kW
Motor overload switch See current circuit diagram
Automatic cutout 8 A characteristic "C"
Communication
Interfaces SMEMA, SV70
Network connection 100 Mbit / 1 Gbit Ethernet
System computer
Operating system Microsoft Windows
®
Processor Intel
®
processor technology
Technical specifications
Environmental conditions
253
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Environmental conditions
This section describes the environmental conditions for operation
and storage.
The environmental conditions are divided into:
Operating conditions (Page 253)
Storage conditions (Page 253)
Operating conditions
Storage conditions
Operating conditions
Permissible weight load for the
ground surface
950kg/m
2
Permissible weight load for the
ground surface (per system foot)
39 N/cm
2
Ambient temperature 5°C to 35°C
Humidity to 80%, not condensed
Average humidity <60%
Storage conditions
Permissible weight load for the
ground surface
950kg/m
2
Permissible weight load for the
ground surface (per system foot)
39 N/cm
2
Ambient temperature 0°C to 70°C
Humidity to 80%, not condensed
Average humidity <60 %