X7056_Operating manual_en.pdf - 第253页

Technical specifi cations Environmental condi tions 253 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a Environmental condit ions This section describes the enviro nmental cond…

100%1 / 280
Technical specifications
System specifications
252
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
System specifications
This section provides general technical information of the inspec-
tion system.
The following data are presented:
Electrical specifications (Page 252)
Communication interfaces (Page 252)
Noise emission (Page 252)
System computer (Page 252)
Electrical specifications
Communication interfaces
Noise emission
The noise level of the inspection system is under 70 db.
System computer
Electrical specifications
Power supply 230/400 VAC, 50/60 Hz, 3 phase, N, PE
Power supply with internal
transformer for main power
adaptation
190 V - 600 VAC, 50/60 Hz, 3 P/N/PE
Average power consumption 0.78 kW/h
Max. Power 1.5 kW
Min. Power 0.62 kW
Motor overload switch See current circuit diagram
Automatic cutout 8 A characteristic "C"
Communication
Interfaces SMEMA, SV70
Network connection 100 Mbit / 1 Gbit Ethernet
System computer
Operating system Microsoft Windows
®
Processor Intel
®
processor technology
Technical specifications
Environmental conditions
253
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Environmental conditions
This section describes the environmental conditions for operation
and storage.
The environmental conditions are divided into:
Operating conditions (Page 253)
Storage conditions (Page 253)
Operating conditions
Storage conditions
Operating conditions
Permissible weight load for the
ground surface
950kg/m
2
Permissible weight load for the
ground surface (per system foot)
39 N/cm
2
Ambient temperature 5°C to 35°C
Humidity to 80%, not condensed
Average humidity <60%
Storage conditions
Permissible weight load for the
ground surface
950kg/m
2
Permissible weight load for the
ground surface (per system foot)
39 N/cm
2
Ambient temperature 0°C to 70°C
Humidity to 80%, not condensed
Average humidity <60 %
Technical specifications
XM camera technology
254
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
XM camera technology
Configuration of the XM sensor head
Variant Illumi-
nation
Resolution in
pixels per
camera
Number
of
orthog-
onal
cameras
Number
of
angled
cameras
Orthogonal
resolution
in µm/pixel
Angled
resolu-
tion in
µm/pixel
Image
field in
mm
XM white,
red,
blue,
green
Binning:
orthogonal:
2560x2560
1 - 16.6
+/- 1%
- orth.:
40x40
Zoom: ortho-g-
onal:
5120x5120
8.3
+/- 1%
-
XM4 white,
red,
blue,
green
Binning:
orthogonal:
2560x2560
1 4 16.6
+/- 1%
16 (x)
+/-
1.25%/
approx.
20.85 (y)
+/- 2%
orth.:
40x40
angled:
40x40
Zoom: ortho-g-
onal:
5120x5120
angled:
2592x2048
8.3
+/- 1%
16.0 (x)
+/-
1.25%/
approx.
20.85 (y)
+/- 2%
XM8 white,
red,
blue,
green
Binning:
orthogonal:
2560x2560
1 8 16.6
+/- 1%
16 (x)
+/-
1.25%/
approx.
20.85 (y)
+/-2%
orth.:
40x40
angled:
40x40
Zoom: ortho-g-
onal:
5120x5120
angled:
2592x2048
8.3
+/- 1%
16 (x)
+/- 1.25/
approx.
20.85 (y)
+/-2%
Optional: XM 3D camera technology.
Measurement
area
25 mm
Z-resolution 0.5µm