X7056_Operating manual_en.pdf - 第91页
Installation First use 91 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a First use First use takes place afte r the inspection system is installed. This section describes the …

Installation
Integrating the inspection system into the line
90
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Information
about the
network
connection
The system computer contains the network connection plug.
Connection to the company network is through a network cable via
RJ-45 connections in the available Ethernet network structure.
The RJ-45 connectors are pre-set to DHCP for connection to the
company's network. Converting the network card properties is only
required when fixed IP addresses are assigned by the customer.
Settings for the host name and domain membership have no
meaning for the inspection system function and should be adapted
to the requirements of the customer network.
Connecting
network
NOTICE
Connection to the company network and its configuration should
be done by the company's network administrator.
ATTENTION
Operation malfunctions
Incorrectly addressing the internal network will prevent the inspec-
tion system from functioning.
The connections X30 LAN and X22 are only for internal commu-
nication and must not be connected to the company network.
Perform the following work steps:
Connect the system computer to the company network with the
help of the current circuit diagram.
The network is connected.

Installation
First use
91
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
First use
First use takes place after the inspection system is installed. This
section describes the steps for first use.
The work steps in detail:
Switching on the inspection system (Page 91)
Checking the safety features (Page 92)
Checking the Interlock linkage (Page 100)
Checking the SMEMA protocol (Page 101)
Checking the SV70 protocol (Page 103)
Checking the PCB transport (Page 104)
Checking the calibration (Page 105)
Checking the network connections (Page 105)
Checking the data transfer to the verification station (Page
106)
Checking the data transfer to the SPC server (Page 106)
Switching on the inspection system
The first step to first use is switching on the inspection system.
Switching on the inspection system is divided into the following
steps:
Switching on the system (Page 91)
Logging on (Page 92)
Switching on
the system
Precondition:
The inspection system is properly installed.
The verification station computer is switched on and has booted
up.
The external in- and outfeed conveyors are switched on.
Perform the following work steps:
1. Turn the main switch to
ON.
2. Press the white ON button.
The white ON button lights up.
All control elements are supplied with current.
? The white ON button does not light up?
The STOP mode is actuated.
See „Checking the Interlock linkage“ (Page 100)
3. Set the key switch to
ON.

Installation
First use
92
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
4. Turn on the UPS devices.
The system computers boot up.
5. Switch on the monitor.
The monitor displays the WindowsREGISTRATION WINDOW.
The inspection system is switched on.
Logging on
NOTICE
The user name si and the password viscom are default settings.
These settings can be customized. Adapting the configuration must
be done by Viscom service personnel.
Perform the following work steps:
1. Press the key combination
Ctrl+Alt+Delete.
The monitor displays the Windows Registration Window.
2. Enter the user name
si and the keyword viscom.
Log on is successful.
Checking the safety features
Make sure the safety features are working properly at first use and
each time the system is switched on.
The work steps in detail:
Checking the STOP mode (Page 93)
Checking EMERGENCY STOP (Page 93)
Checking the lift gate functioning (Page 94)
Checking the shutter functioning (Page 97)