Weekly PM (70x) - Preparat ions f or Maintenance – vacuum test : 170 Preparat ions for M aintenan ce – vacuum test The vacuum test is used t o check the condition of th e nozzles and segments. 1. Select ‘Manual Operation…

Weekly PM (70x) - Preparations for Maintenance – stop production. :
169
Preparations for Maintenance – stop production.
1. Select the ‘Manual Operations’ window.
2. Click – ‘Do not change production status’.
This will prevent production from starting again until you
want it to.

Weekly PM (70x) - Preparations for Maintenance – vacuum test :
170
Preparations for Maintenance – vacuum test
The vacuum test is used to check the condition of the
nozzles and segments.
1. Select ‘Manual Operations’ menu.
2. Select – ‘Check sensors and functions of specific
components’.
3. Select - ‘CPP head’ – or any other head fitted to the
machine.

Weekly PM (70x) - Preparations for Maintenance – vacuum test :
171
Preparations for Maintenance – vacuum test
CPP head functions menu.
1. Select – ‘Check vacuum, height and scan values’
icon.