SECS GEM Manual - 第110页
GEM Manual for DEK Printers Equipment Variables Issue 1.6 January 22, 2018 Page 110 of 171 ToolingHardware 62 The currently selected tooling harware U1 0=Magnetic 2=Vacuum 6=FormFlex 7=GridLok 8=ProductDefined 9=Enhanced…

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 109 of 171
spooling_enabled 16 Allows the equipment to default to a
condition where spooling is disabled
completely. This is provided for older
Hosts that do not support S6F23. This
EC is set to TRUE = 1 on receipt of
S2F43 defining messages to be
spooled.
B1
0 = FALSE spooling
disabled
If the Host sets this
EC to FALSE any
data in the spool will
be purged.
Yes
Reserved 17-
39
Not used by the 265.
TimeFormat 40 The setting of this ECV controls
whether the equipment shall send the
Data Items STIME and TIME in 12-
byte or 16-byte format. It also
controls the format of
START_TIME. to be 6 or 7 bytes.
B1 0 = 12 byte format
1 = 16 byte format
>1 reserved
Yes
RunGEMRemote 41 Allows control of the Run With GEM
Remote parameter. When enabled,
only the host can start the printer and
the operator is given an appropriate
message.
U1
0 = Disable
1 = Enable
Yes
CompoundProductFiles 46 Controls whether Compound Product
functionality is enabled or disabled.
U1
0 = Disable
1 = Enable
Yes
Make 50 Printer make. Always returns “DEK” A20
“DEK”
No
Model 51 The model of the printer A20 For example
“Galaxy”
No
StencilCleaningSystem 53 The currently selected cleaner
module
U1
0 = None
1 = Blue
2 = Vortex
3 = Cyclone
4 = Cyclone Duo
No
ApplicatorType 54 The currently selected applicator
module
U1
0 = Squeegees
1 = ProFlow (classic)
2 = Ball Placement
3 = ProFlow Tx
4 = ProFlow ATx
No
ConveyorType 55 The fitted conveyor type U1
0 = Standard
1 = HTC
2 = RTC
No
TransportMode 56 The current rail transport mode U1
0=LeftToRight
1=RightToLeft
2=RightToRight
3=LeftToLeft
4=NoTransfer/Shuttle
Yes
MachineUnits 57 The current machine units U1
0=Metric
1=Imperial
Yes
UplineProtocol 58 The current up-line FMI protocol U1
0=NoFMI
1=MIU
2=Manual
Yes
DownlineProtocol 59 The current downline FMI protocol U1
0=NoFMI
1=MIU
2=Manual
Yes
TransferPeriod 60 FMI transfer period (s) U2 0 – 999, 20 Yes
PasteDispensePosition 61 The position the paste dispenser uses U1 0=Front
1=Rear
2=Auto
Yes

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 110 of 171
ToolingHardware 62 The currently selected tooling
harware
U1
0=Magnetic
2=Vacuum
6=FormFlex
7=GridLok
8=ProductDefined
9=EnhancedVacuum
No
FiducialReference 63 The current fiducial reference U1
0=Left
1=Right
Yes
ProductBarcodeHardware 64 The status of the product barcode
scanner
U1
0=Not Fitted
1=Fitted
No
RemoteBarcodeHardware
65 The status of the remote barcode
scanner
U1
0=Not Fitted
1=Fitted
No
AdvancedProflow
66 Status of the Advanced ProFlow
option
U1
0=Disabled
1=Enabled
Yes
PressureHardware
67 The currently selected pressure
hardware
U1
0=NotFitted
1=Fitted
No
PasteDispenser 68 The status of the automatic paste
dispenser
U1
0=NotFitted
1=Fitted
No
ScreenSize 69 The current screen type selection U1
0=265
1=Fuji
2=249
3=Sanyo
4=Library
Yes
RollHeightHardware 70 The current selection of the Paste
Roll Height Monitor (PRHM)
hardware
U1
0=NotFitted
1=Fitted
No
RollHeightMonitor 72 The current status of the PRHM
option
U1
0=Disabled
1=Enabled
Yes
ConsumableAction 73 The current setting for the action to
perform when a consumable is low
U1
0=Warn
1=Pause
2=Suspend
Yes
VacuumHoldTime
74 The time the vacuum is applied to the
tolling before the quality of the
vacuum seal is checked (s)
F8 0-5 s Yes
TwoDiMovementTuning
75 The settling time used in 2D
Inspection per site (ms)
U2 0-250 ms Yes
CleanerVacuum
76 The current status of the cleaner
vacuum option
U1
0=Standard
1=Vacuum
No
PasteTrails
77 The current status of the paste trails
option
U1
0=Disabled
1=Enabled
Yes
TransportWaitMode 78 The current setting for the transport
wait mode
U1
0=Standard
1=Hold At Print
Yes
ClampType
80 The current selection for the board
clamp type
U1
0=Board Clamps
1=Snuggers
2=Foil Less Clamps
3=Over The Top
Snuggers
No
ToolingMonitoring
81 The rate (in boards) that the Tooling
Deviation Monitoring option is used
U2 0 – 200 Yes
FiducialMonitoring
83 The current selection for the Fiducial
Monitoring option
U1
0=Smart
1=Normal
Yes
FiducialSearch
84 The current selection for the Fiducial
Search option
U1
0=Disabled
1=Custom
Yes
RemoteBoardStopHardware 85 The current selection for the Remote
Board Stop hardware
U1
0=NotFitted
1=Fitted
No

GEM Manual for DEK Printers Equipment Variables
Issue 1.6 January 22, 2018 Page 111 of 171
BoardStopXOffset
86 The current camera board stop X
offset
F8 25-254 mm No
CameraIdlePosition 88 The current selection for the Camera
Idle Position option
U1
0=Home
1=Behind Rail
No
UnloadBoardStart
89 The current selection for the Unload
Board Start option
U1
0=Transport
1=Separation
Yes
MaintenanceMonitoring
95 The current state of the Maintenance
Monitoring option
U1
0=Disabled
1=Enabled
Yes
MachineLocation
96 Free format entry to describe the
location of the machine
A20 Up to 20 characters No
AutoRailWidth
97 The current selection for the
Automatic Rail Width option
U1
0=Disabled
1=Enabled
No
ProductDirectory
98 The path to the local folder where the
product files are stored
A260 Up to 260 characters No
DataFileLocation 99 The path to the local folder where
data and log files are stored
A260 Up to 260 characters No
DownlineBoardStop
101 The current selection of the HTC
Downline Board Stop option
U1
0=Never
1=Always
2=Auto
Yes
FrontRToLSpeed
104 The speed of the front rail belt when
running from right to left
U2 0-32000- 64000 No
FrontLToRSpeed
105 The speed of the front rail belt when
running from left to right
U2 0-32000- 64000 No
RearRToLSpeed
106 The speed of the rear rail belt when
running from right to left
U2 0-32000- 64000 No
RearLToRSpeed 107 The speed of the rear rail belt when
running from left to right
U2 0-32000- 64000 No
AltFrontRToLSpeed
108 The alternate speed of the front rail
belt when running from right to left
U2 0-32000- 64000 No
AltFrontLToRSpeed
109 The alternate speed of the front rail
belt when running from left to right
U2 0-32000- 64000 No
AltRearRToLSpeed
110 The alternate speed of the rear rail
belt when running from left to right
U2 0-32000- 64000 No
AltRearLToRSpeed
111 The alternate speed of the rear rail
belt when running from right to left
U2 0-32000- 64000 No
VacuumPressureRequired 153 The current value of the Vacuum
Pressure (Required) parameter
F8 -100 - -35 - 0 Yes
VacuumValve 154 The current value of the Vacuum
Valve parameter
F8 0 – 100% Yes