SECS GEM Manual - 第158页
GEM Manual for DEK Printers Additional Capabilities Issue 1.6 January 22, 2018 Page 158 of 171 DVNAME Table: DVNAME De scription DVVAL 0 Current process program <PPID> 1 Operator name 1-20 character ASC II string 2…

GEM Manual for DEK Printers Additional Capabilities
Issue 1.6 January 22, 2018 Page 157 of 171
9.2 Upload Management Information
Host to Equipment
The equipment will receive a Data Transfer Request message Stream 6 Function 7, requesting
Management Information. The equipment will respond with a Data Transfer Data message Stream 6
Function 8, containing the Management Information as detailed below or if it cannot process the
message or an error occurs containing a zero length string.
Host requests that the equipment transfer the management information file to the host:
Comments Host Equipment Comments
Host requests upload of
Management Information.
S6F7 -->
<-- S6F8
<-- S6F8
[IF] equipment System Status = READY
upload Management information
[ELSE] file is not transferred
<L,0>
[END_IF]
Host to Equipment Message Structure:
Stream 6 Function 7
<DATAID> 0 = MANAGEMENT DATA, 2 byte signed integer
Equipment to Host Message Structure:
Stream 6 Function 8
L,3
1. <DATAID> 0 = MANAGEMENT DATA 2 byte signed integer
2. <CEID> 0 = HOST REQUEST 2 byte signed integer
3. L,2
1. <DSID> 0 = MANAGEMENT DATA 2 byte signed integer
2. L,n
1. L,2
1. <DVNAME 1>
2. <DVVAL 1>
.
.
n. L,2
1. <DVNAME n>
2. <DVVAL n>

GEM Manual for DEK Printers Additional Capabilities
Issue 1.6 January 22, 2018 Page 158 of 171
DVNAME Table:
DVNAME Description DVVAL
0 Current process
program
<PPID>
1 Operator name 1-20 character ASCII string
2 Counts 3 x 4 byte integers, Batch, Session, Total.
3 Batch start time <START_TIME>
4 Session start time <START_TIME>
5 Waiting times <MDTIME>
6 Running times <MDTIME>
7 Setup times <MDTIME>
8 Down times <MDTIME>
9 Recovery times <MDTIME>
10 Maintenance times <MDTIME>
MDTIME
Description:
Management Data Time, is a variable data structure used in reporting management information.
It consists of three six byte binary values containing a time in hours minutes and seconds for the
Batch, Session and Total timers.
Format:
Unsigned integer 6 bytes long
Batch time
Unsigned integer 0 Seconds
1 Minutes
2 Hours
Session time
Unsigned integer 0 Seconds
1 Minutes
2 Hours
Total time
Unsigned integer 0 Seconds
1 Minutes
2 Hours
Length:
18 bytes
Where used:
S6F8

GEM Manual for DEK Printers Additional Capabilities
Issue 1.6 January 22, 2018 Page 159 of 171
START_TIME
Description:
Variable data type used in reporting Management information. The format depends on the
value of TimeFormat.
Short Format:
binary
byte 0 Seconds 0 to 59
byte 1 Minutes 0 to 59
byte 2 Hours 0 to 23
byte 3 Day 1 to 31
byte 4 Month 1 to 12
byte 5 Year 0 to 99
Long Format:
binary
byte 0 Seconds 0 to 59
byte 1 Minutes 0 to 59
byte 2 Hours 0 to 23
byte 3 Day 1 to 31
byte 4 Month 1 to 12
byte 5 Year (LSB) } 0 to 9999
byte 6 Year (MSB) }
Length:
6 bytes or 7 bytes
Where used:
S6F8.