Chap ter3 SPC User Ma nual AOI Repair Station 147  In addition, you can query the Alarms Log. When an alarm (error) occurs, the system will save a record in the Alarm s Log. From the Main menu, you can click on “ Alarm”…

100%1 / 168
Chapter3 SPC User Manual
AOI Repair Station
146
Style 3 Report
3.儲存成功訊息!
1. Click on [Excel] and select Style 3
2. Report Parameters Setting
Select the data that user wants to output besides
statistic data and control chart in Excel file. User
can select:
Program Name
Print Date
Spec Data
Inspection time and barcode for every sample:
the inspection time and barcode for the board
that every sample belongs to.
If samples are not enough, left empty rows for
the lack of samples: When the samples are not
enough, there are empty rows left for user to
key in manually. The number of samples is
time period divided by interval.
Chapter3 SPC User Manual
AOI Repair Station
147
In addition, you can query the Alarms Log. When an alarm (error)
occurs, the system will save a record in the Alarms Log. From the
Main menu, you can click on “
Alarm” and then “Alarms Log” to
display the Alarm Log window as shown below.
4. Review Excel Data
P.S. If you change a sample data in this report, the relating statistic data and control chart will be changed.
A monitored item uses a sheet to
output data.
The last Sheet is the temporary
zone, don’t delete it.
These rows are reserved for
user to key in data manually.
Chapter3 SPC User Manual
AOI Repair Station
148
All alarm logs are saved by date. That is to say, all alarm logs for one
day are saved as one file and named in this format:
“alarms”_year-month-day.”xml”. For example, the
“alarms_20041209.xml” file stores all alarm logs for December 9,
2004. You can view all alarm log files from the “Alarms Files List”
window on the left side of the “Alarms List” block under the task bar.
Once this window is opened, the system loads today’s alarm log files
by default. You can click on the alarm log file to be viewed to load
the current alarm log anytime and display it in the message list on the
right.
Click on any message in the list and the Alarm Message block on the
lower part of the screen will display all detailed information regarding
this message. Below is the description of each item:
GUID: Message no. The system automatically assigns a unique
ID number for each alarm message.
Time: Time the message occurs.
Click on this icon to open the
window of Alarm Voice Setting.