Detailed Circuit Diagram Folder SIPLACE F5 - 第83页

2 Circuit Diagr ams 83 I 0032151 0-070 201LD3 Circu it diagr am, ter minal pane l, right- hand side 45 6 7 8 17 2L+ 9 X206: L1 34 5 6 X206: L2 (rd) (re) X2 X1 1 (K1) 34 56 12 3 45 6 7 1mm ² N X2 X2 PE PE PE PE X1 12 N N …

100%1 / 143
2 Circuit Diagrams 82
I
00334647-010101TD3 F5 servo unit, basic module (viewed from the back) (Sh. 3 of 3)
10 21
10
510 19 32
51 56 63 68
Fan unit
X3X2
X4
X80
A14
A13
Y-axis
X-axis
Y-axis
X-axis
X14
Y motor
X6
X motor
X5
Ballast circuit
Power supply unit
Dynamic brake, Y
Dynamic brake, X
Anti-crash board
Siemens AG
1
1
243
2345678
A
B
C
D
E
F
A
B
C
D
AUT5-BSM
A16
X4
Z-axis
X2
X1 (vd)
X3
X4
X3
A17
X2
X1 (vc)
A18
X4
DR-axis
X2
X1 (vg)
X3
A19
X4
Z-axis
X2
X1 (vk)
X3
1:2
(viewed from the back)
16 27 49 60 71
38
X11
X7
X1 (va)
X5X4
X6
X2
X7
X1 (vb)
X6
X5X4
X2
1-84 (2mm)
Numerical tape
60x30 l=300mm
60x30 l=300mm
Cable duct 003
Cable duct 002
60x30 l=300mmCable duct 001
30x30 l=250mm
Cable duct 004
38
X12
X13
29
X7
X8
SMD-Placement System Siplace 80F4
Product status
Doc. status
Function status
6-nozzle revolver head
"A20"
Sheet
Sh.
Mat-Nr.:
CAD-Datei:
Status Modified Date Name
Stand.
Check.
Author
Date
Scale
Servo unit 80F4 / 6 base
17.06.1997
Tekin
00334647-01
334647T1
1.
16.09.97
1.
Tek
1.
16.09.97
16.09.97
Tek
Tek
00334647-010101TD3
X3 X3
IC head
IC head
SP head
SP head
SP head
Star
A15
X4
DP1-axis
X2
X1 (vf)
X3
2 Circuit Diagrams 83
I
00321510-070201LD3 Circuit diagram, terminal panel, right-hand side
456 78
17
2L+
9
X206:L1
3456
X206:L2
(rd) (re)
X2
X1
1
(K1)
34 56
123 456 7
1mm²
N
X2
X2
PEPEPEPE
X1
12
NN
56
L2 L3L1
3
L1 4L3 L3L2L2 6
1413 15 16
2L+
1L+ 11
12
1L+ 2
2L+ 3
10mm²
1mm²
89
(rc)
6
4
X206
X207
1
5
C0530
2
Y636-
Y636-
C0530
C938
5L+
PE PE
1L+
1L+
1L+
1L+
(rb)
PEPENN 5
(+24V)
L1
2L+/5L+
2L+/5L+
2L-
1L-
1L+ 4
1L+ 1
7
10mm²
C510-W1
6
3
3
2
6mm²
6mm²
C709
C708
X31
*938/X16
2L+
2L-
2
9
8
D
7
C
A
6
D620-W1
10
8
3
5
56
1mm²
F
342
2
B
A
1
1
1
8
4L+
18 8 8
1mm²
5
10 19 11
1
4
72345
12
X1
12398711
4
76
3
C
D
E
00344540
E
F
00344539
4
1mm²
7
X1
PEN5PEN4
-xx-xx
C511-W1
10 10
6
6L+ 9
7L+ 10
2L+/5L+
3
1
2L-
5
2
1mm²
2L-
C560
6
1
7
3
21
6
L3 PE
*904/X211,X212
K504-W1
(K2)
*935/X3
Y510-W1
*935/X2
C509-W1
2L- 8
D619-W1
(K1)3L+ 5
X206:PE
X206:N
X206:L3
X206:L2
X206:L1
X206:PE
X206:N
X206:L3
18
89
A2
A3 A4 A5
34
L1 L2
R1
21
PL EA1 E
Function status
Product status
Document status
SMD Placement System SIPLACE 80S20/F4
Sheet
Sh.
Status Modified Date Name Stand.
Check.
Author
Date
Orig. Creat. f. Creat. by
Terminal panel, righthand side
Terminal panel
To
Servo unit
To
Servo unit
To
Tape cutter 1
To To
Tape cutter 2
To
Servo
Star point 007
wh
bl&bk
bl&bk
bl&bk
0.5mm²
6L+ unswitched
+7L switched
+7L switched
6L+ unswitched
4.7 Ohm / 5W
bk
bk
1.0mm²
1.5mm²
To
To
WPC interface
righth. side D911
lefth. side, D910
WPC interface
Power supply
To
Power supply
VI rectifier
To
in SIPLACE 80F4 machines only
WPC interface:
ToToTo
Control unit Interface Interface
lefth. side, C955 righth. side C956
To
Power supply
Power supply
SC
To
Option:
From UPSTo UPS
br
br
gn
gn
wh
wh
bk bk
wh
gr
bk
1.5mm²bk
br
gn
ye
gr
pk
bl
wh
Spare
bl&bk
bl&bk
bl&bk
gn
bk bk
wh
wh
gn
gn
wh
wh
wh
gn
ye
gr
wh
br
br
gr
ye
wh
pk
gr
bk
gn&ye
gn&ye
bk
gn&ye
gn&ye To servo unit
To control unit
To cable
To cable
br
bl
gn&ye
br
bl
gn&ye
wh
pk
bk
wh
wh
bl
br
gn&ye
bl
bkbk
bl
bl
bl
rd
br
gr
wh
br
br
br
gn&ye
gn&ye
gn&ye
gn&ye
gn&ye
bl
br
gr
gn&ye
rd
wh
br
wh
wh
gn&ye
br
bl
gn&ye
gn&ye
bl
bk
br
bk
gn&ye
bk
bk
br
bk
bl
When using
a UPS, connect
the cables and
remove jumper
X206:4-5 !
=
SIEMENS AG
+
00321510-070201LD3#
Tuth
21.10.98
08.06.98
01.06.00
21.10.98
01
02
07
Leh
Tu.
Leh
C523-W100300161-06Y511-W1 C516 C517
C506-W1
*952
1
X1
11
4
1
2
(K1)
2
12V
4
6
2L-
1mm²
1mm²
1mm²
C935
5
7L+ 10
6L+ 9
PE
2
(K2)
5
2
1L-
B
2
(K2)
(+24V)
4
1
1
456
123
2 Circuit Diagrams 84
I
00321510-070201TD3 Terminal panel, right-hand side
=
SIEMENS AG +
L3
N
1
X
18
XX
XX
X
C
234 7
L1
56
X207
A
10
10
N
N
X
13
17
18
6
11
12
19
X
X
X
PE
B
A
420,0mm
F
L2
X2rd
L3
L3
X1re
4
D
E
F
C
X
14
15
16
5
315,0mm
5
D
L2
2
B
C
5
6
4
PE
PE
10
X1rc X1rd
XX
2 6
PE
PE
PE
A4
A5
X2rb X2rc
3
X1rb
AA-BBBB-CCCC
N
PE
PE
00321510-07
SIEMENS PLEA 1
A
B
1
END
E
D
500,0mm
XX
XXX
L1
78
252,0mm
190,0mm
N
L2
8
XX
X206
1
8
9
3
L1
L1
PE
PE
N
40
20
4
A2 A3
1
7
8
1
L3
01
01
07
Leh
Leh
Leh
XX
116,0mm
XX
L2
PL EA1 E
00321510-070101TD3
#
Tuth
21.10.98
08.06.98
08.06.98
21.10.98
Function status
Product status
Document status
SMD Placement System SIPLACE 80S20/F4
Sheet
Sh.
Length for cable ducts +/- 5mm !
Please note:
Terminal panel, righthand side
Font size: 2.5mm, material: Scotchcal 3698-E (color: A1 RAL 9006)
BBBB = date (year/month/day) acc. to SN 01007
AA = manufacturer/location acc. to SN 37040
Assembly inscription acc. to VA - F - 510 - 001 guideline
CCCC = series number
Creat. by
D: space for voltage label from NAFTA label set (for USA only)
B: inspection label
A: identification label
C: ground label
Identification: testing engineer, month, year
Orig. Creat. f.Stand.
Check.
Author
Date
NameDateModifiedStatus
The following labels have to be applied:
to 4L+ (8V),
This way you will switch from 1L+ (100V)
and insert it at X207 11-12-13-14-15.
remove the jumper from X207 13-14-15-16-17
- when commissioning the X,Y axes the first time
thus reducing the crash risk.
Please note:
Ground connection
acc. to constructions specs 00343603, sh.2
0.0mm
35.0mm
Screw
SN 70093 contact washer
DIN 439 nut
Annular cable lug
DIN 125 washer
DIN 7980 split washer
DIN 439 nut
Please note: Break off one rib at each X !
Cable duct: 65x66 l=460mm
Cable duct: 65x66 l=340mm
Please note: break off one rib at each X !
80.0mm
30.0mm
230.0mm
Cable duct: 65x46 l=400mm
Please note: Break off one rib at each X !
Cable duct: 65x46 l=400mm
Please note: Break off one rib at each X !
110.0mm