Setting up and Commissioning Installation and Commissioning the SILPACE E User Manual JTF-MW on SIPLACE E 33 Installing the Frame Kit The frame kit acts as a stop and prevents the JTF-MW from tilti ng. 4.6 4 . 6 I n s t …

100%1 / 68
Setting up and Commissioning
Preparatory Work
32 User Manual JTF-MW on SIPLACE E
Replacing the Empty Tape Duct
Remove the plug at the front cover (1).
Push the coupling through the opening in the front
cover (2).
Fix it with a nut.
Close the side cover inside the machine and fix it with
the three screws that you previously removed.
In the original state, the SIPLACE E machine is equipped
with a long empty tape duct (1).
Remove the fastening screws on the left side and on
the right side of original empty tape duct.
Lift the empty tape duct out of the machine.
Install the empty tape duct 25 mm right (1).
Fix the empty tape duct with two M5x10 screws on
the left (2) side and on the right side (3).
Setting up and Commissioning
Installation and Commissioning the SILPACE E
User Manual JTF-MW on SIPLACE E 33
Installing the Frame Kit
The frame kit acts as a stop and prevents the JTF-MW from tilting.
4.6
4.6 Installation and Commissioning the SILPACE E
Installation and Commissioning the SILPACE E
4.6.1
4.6.1 Installing the JTF-MW in the Machine
Installing the JTF-MW in the Machine
Install the frame kit (1) at its installation position on
the left of the empty tape duct.
Fix it at the two fixation points (2).
COT in loading position
Move the COT table to the loading position so that the
table is in a fixed position when installing the
JTF-MW.
Setting up and Commissioning
Installation and Commissioning the SILPACE E
34 User Manual JTF-MW on SIPLACE E
JTF-MW in SIPLACE E machine
Remove all JEDEC trays from JTF-MW to reduce the
weight.
Together with a second person, lift the JTF-MW by its
handle and carry it to the machine.
Position the JTF-MW on tracks 1 to 30.
Slide the JTF-MW into the machine (1) until the stop
at the frame kit.
JTF-MW fixed at COT
Fix the JTF-MW at the indicated positions to the COT
using two washers (ISO 7092 5) and two M5x20