00197469-02_SM_Twin_Kunde_EN - 第28页

4 Pneumatic and pressure control valve (PRV) 4.2 Replacing the pressure control valve (PRV) 28 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 Fig.27: Screws fastening the air filter (example of Twin /…

100%1 / 92
4 Pneumatic and pressure control valve (PRV)
4.2 Replacing the pressure control valve (PRV)
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 27
4.2 Replacing the pressure control valve (PRV)
NOTICE
Head board function state
The head board must have a function state of at least 09.
NOTICE
Converting the analog/digital PRV
To convert the analog PRV to a digital one, read the retrofit instructions "Digital pres-
sure control valve and new TH air filter" [DEEN:00196286‑xx].
Parts
Digital pressure control valve for the TwinHead [03058802-xx] (suitable for all Twin types)
Overview
Fig.26: PRV and air filter (example of Twin VHF shown)
1. Air filter assembly [03051420-xx]
2. Screws fastening the air filter
3. Digital pressure control valve for the
TwinHead [03058802-xx]
In contrast to the analog version, the digital
PRV has a thin high-precision tube (addi-
tional volume tube) in the vacuum supply to
the nozzle. Between this tube and the
vacuum connection of the PRV, there is an
air filter attached to the Twin module.
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Removal
Dismantle the buffer on the return unit.
3.1 "Replacing the return unit buffer" [}17]
For Twin VHF only:
Dismantle the head main board.
(in the Twin VHF the PRV is removed upwards, in the Twin and Twin HF, it is pulled sideways
out of the head.
5.1 "Replacing the head main board" [}65]
4 Pneumatic and pressure control valve (PRV)
4.2 Replacing the pressure control valve (PRV)
28 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
Fig.27: Screws fastening the air filter (example of Twin /
Twin HF shown)
Only for Twin / Twin HF:
Loosen the two screws(1) fastening
the air filter, so that the air filter can be
moved easily but the screws can not
fall out.
Fig.28: Push the air filter into the head (example of Twin /
Twin HF shown)
Only for Twin / Twin HF:
Turn the air filter onto its side(1) and
push it through the opening(2)
into the
inside of the head.
Fig.29: Screws fastening the air filter (Twin VHF)
Only for Twin VHF:
Take off the filter cap and remove the
two screws(1)
fastening the air filter,
so that the air filter can move freely.
4 Pneumatic and pressure control valve (PRV)
4.2 Replacing the pressure control valve (PRV)
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 29
Fig.30: Pull off the hose (example of Twin / Twin HF shown)
Pull the bottom hose off the precision
tube.
Fig.31: Screws fastening the PRV (example of Twin / Twin
HF shown)
Remove the two screws fastening the
PRV.
Only for Twin / Twin HF:
Pull the PRV downwards, to unplug it
from the head main board.
Fig.32: Remove the PRV (example of Twin / Twin HF
shown)
Only for Twin / Twin HF:
Pull the PRV and air filter sideways out
of the head together.