00197469-02_SM_Twin_Kunde_EN - 第58页

4 Pneumatic and pressure control valve (PRV) 4.8 Replacing the force measuring unit and the trick and feather unit 58 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 4.8.3 Assembly Fig.101: Screws fast…

100%1 / 92
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 57
Fig.99: Screws fastening the force measuring unit
Fig.100: Washer
Hold the rotary unit securely.
Remove the left screw.
Remove the righthand screw in the
pipe clamp.
Take the force measuring unit off the
trick and feather unit.
 NOTICE!
Plastic washer!
Take care not to lose the plastic
washer. This is located under the pipe
clamp.
.
 NOTICE!
Third spacer!
If you are replacing the force measur-
ing unit, dismantle the third spacer.
.
CAUTION
Do not damage the incremental disk!
The incremental disk is now unprotected and could be easily damaged or contaminated.
Handle the trick and feather unit with care so that the incremental disk is not dam-
aged.
Keep the incremental disk clean.
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
58 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
4.8.3 Assembly
Fig.101: Screws fastening the force measuring unit
Fasten the force measuring unit to the
trick and feather unit.
Hand-tighten the two fastening screws.
 CAUTION!
Risk of short circuit!
Make sure that you fit the plastic
washer under the pipe holder.
.
 NOTICE!
Pipe holder!
Align the slit in the pipe holder so that
it is parallel to the edge of the printed
circuit board.
.
Fig.102: Connector
Disconnect the incremental encoder
and the D axis motor.
 CAUTION!
Do not damage the D axis connec-
tion!
The connector on the D axis cable is
easily damaged.
Plug in the connector with care. The
solder points could be easily damaged.
.
Fig.103: Spacer
Fit the two spacers with the short sides
facing upwards and hand-tighten these.
 NOTICE!
Third spacer!
If you are replacing the force measur-
ing unit, fit the third spacer.
.
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 59
Fig.104: Grub screw for fly wheel
Fit the fly wheel and fix into place with
the two grub screws.
Fig.105: Fitting the rotary unit
Fit the rotary unit to the Z axis shaft
and hand-tighten the two screws.
 CAUTION!
Do not damage the incremental
disk!
The incremental disk is now access-
ible, down at the rotary unit.
Handle the rotary unit with care. The
incremental disk can be easily dam-
aged or contaminated.
.
Fig.106: Z axis motor connector
Connect the Z axis motor.