80S20 circuit - 第85页

3 SIPLACE 80S-20 Circuit Diagrams 85 00344265-020101 TD3 T erminal panel (lef t-hand side) PL EA1 E 5 02.09.99 02.09.99 00344265-020101TD3 # Haas 02.09.99 02.10.98 22 22 23 24 25 1 0V 0V X1kd 5 EA 8 X1ki XX A4 240mm 1 1 …

100%1 / 138
3 SIPLACE 80S-20 Circuit Diagrams 84
00344265-020101LD3 Terminal panel (left-hand side) (Sh. 2 of 2)
wh&br
gn&ye
bn
pk
gy
ye
gn
wh
gn
ye
bn
wh
pk
gy
GND bus bar
ye
bl&rd
bk
pk
gy&pk
rd&bl
bn
wh
vio
gy
gn
bk
wh/gn/gy/bl
wh/gn/gy/bl
ye/pk/rd
bn
ye/pk/rd
bn
bn
bn
wh
bn
bn
wh
wh
wh
gy
gn
ye
pk
gn
pk
gy
ye
From feeder crash sensor, right CO-table, S4
To feeder crash sensor, right CO-table, S4
From feeder crash sensor, right CO-table, S3
To feeder crash sensor, right CO-table, S3
From feeder crash sensor, left CO-table, S2
To feeder crash sensor, left CO-table, S2
From feeder crash sensor, left CO-table, S1
To feeder crash sensor, left CO-table, S1
To feeder crash sensor, Spare 4
From feeder crash sensor, Spare 3
To feeder crash sensor, Spare 3
From feeder crash sensor, Spare 2
To feeder crash sensor, Spare 2
From feeder crash sensor, Spare 1
To feeder crash sensor, Spare 1
From CO-table (E-S-L)
+30V unswitched
+30V switched
+30V switched
+30V switched
+30V unswitched
+30V unswitched
+30V switched
wh
gn
bn
wh&gr
gy&br
pk&bn
bl/bk
+30V switched
=
SIEMENS AG
+
F
E
454
5ki P
+12V
X
8X
D
+24V
P
2
2kf
2ke
5
U
+24V
2011
+24V
+24V
+24V
+24V
+24V
X
76
2kd
8
1
X212
00322111-xx
X211
7
*(00344213-xx)
*(00344261-xx)
*(00344260-xx)
*(00344277-xx)
*(00344276-xx)
4208 5
2kc
X210
21
00xxxxxx-xx
6
+
X210
2
32 8
00xxxxxx-xx
00xxxxxx-xx
00xxxxxx-xx
25
X212
26 26
20 6
27 27 28 28 29 29 30 30 31 31 32
Ha
Leh
02
01
02.09.99
02.10.98
02.09.99
Haas
#
00344265-020101LD3
01 02.09.99
PL EA1 E
Ha
Date
Check.
Author
Creat. byCreat. f.Orig.NameModified DateStatus Stand.
Sh.
Sheet
SMD Placement System SIPLACE 80S20/S23
Document status
Product status
Function status
Circuit diagram, terminal panel
lefthand side
00322104-xx
00303617-xx
(00321421-xx)
Continued on
sheet 1
Hood switch
Option
succeeding
machine
Output conveyor
Hood switch
the jumper
Warning!
(connection rail)
If a hood switch
is connected
has to be removed.
To terminal panel
righthand side
To
Servo unit
***
***
00322105-xx
00322333-xx
0.5mm²
wh
wh
bl/bk
bl/bk
gy
bn&bk
multiplexer
To video
righthand side
WPC interface
To
lefthand side
To
WPC interface
when wiring the module.
In SIPLACE 80S23 machines
both WPW interfaces ***
In SIPLACE 80S20 machines
Jumpers X211 4-5 and
X211 6-7 have to be inserted
these cables are not available.
are available.
Please note:
0.5mm² 0.5mm²
6.0mm²
Ground
(Frame)
Power supply, switched
To
apply to the F5-HM machine.
in brackets
The numbers
* Please note:
Conversion board
Gantry 1
Conv. board
Gantry 2
Conv. board
To
Gantry 1
To
Gantry 2
Conv. board
To To
Control unit
To
S1 switch
Feeder
Crash
CO-table, le
Sensor
Option:
Crash
S2 switch
CO-table, le
Sensor
Feeder
Option:
Crash
S3 switch
CO-table, ri
Sensor
Feeder
Option:
Crash
S4 switch
CO-table, ri
Sensor
Feeder
Option:
Terminals X212/25
to X212/32 are jumpered
(factory setting).
can be connected.
crash sensors
4 more feeder
Please note:
From signaling circuit, protective switch 6
From signaling circuit, protective switch 5
From control circuit, prot. switch 6
To control circuit, prot. switch 6
To control circuit, prot. switch 5
From control circuit, prot. switch 5
K1 signaling circuit
K2 signaling circuit
+30V unswitched
wh
wh
bn
bn
gn
gy
ye
ye
gn
ye
rd
bk
bn
pk
gn
bl
Software release signaling circuit (K3 monitoring)
Control ON, K2 signaling circuit
K3 safety contactor, GND
K3 software release
From Start button to K1
External emerg.-stop circuit (WPC)
Control On, K1 signaling circuit
To Start button from K2
From emerg.-stop circuit to K2
To Start button from K1
From software relay K3
From Start button to K2
Control On, K1 signaling circuit
To software relay K3
Control ON, K2 signaling circuit
Control ON, K2 signaling circuit
Control On, K1
wh&ye
wh&gn
bl&bk
bl&bk
vio
gn
ye
gy&pk
gy
bn&gn
rd&bl
bn
ye&br
bl&bk
bl
bk
wh
From signaling circuit, Emerg.-stop button
To signaling circuit, Emerg.-stop button
From signaling circuit, Emerg.-stop button
To signaling circuit, Emerg.-stop button
To WP changer (E-S-L)
From WP changer (E-S-L)
From WP changer (E-S-L)
To WP changer (E-S-L)
External emerg-stop GND
External emerg-stop GND
External emerg.-stop
External emerg.-stop
gn&ye
gy&pk
X
00321790-xx
-15V
+5V
X5kg
+12V
2ke
12
X210
3
3
+24V
4
P
4
00321426-xx
4
X
GND
43
GND
GND
00305818-xx
GND
+24V
X
3
+24V
M
GND
X
GND
F
E
13
X212
M
10
00321789-xx
P5kg
M
00321787-xx
+24V
X
00321788-xx
+24V
P
G
1
2kb
2ka
2kf
10 3
+24V
+5V
+24V
00321086-xx
22
P
C
B
2kd
2kc
+24V
XM
22
2
-15V
21 21
2kb
2
X211
33
318
M
3
5kg
GND
+5V
6333
X
X
X212
-12V
7
7
2kd
15
00321113-xx
14 21
1
GND
+5V
3
1
X
+
2ka
2kc
2kc
XP
X
16
X
GND
GND
19
2kd
14
GND
+24V
7
X
X
8
10
13-14 X211
X212
4
13
X
00305817-xx
810
00300182-xx
C
B
A
2
5
X
1234
X
974
17
GND
P
+15V
8
X212
10
M5ki
D
X
MX
34
X
M
+24V
5kiX
5kg
-X
2kd
00301485-xx
4
4
2kd
+8V
22 2
+5V
A
+24V
X211
21
X
00306880-xx
U
6
GND
2kb
G5ki
00322112-xx
3 SIPLACE 80S-20 Circuit Diagrams 85
00344265-020101TD3 Terminal panel (left-hand side)
PL EA1 E5
02.09.99
02.09.99
00344265-020101TD3#
Haas
02.09.99
02.10.98
22 22
23 24
25
1
0V
0V
X1kd
5
EA
8
X1ki
XX
A4
240mm
1
1
2
X
X2kdA
2
XX
80mm
A3
2
2
6
30mm
X
XX
20 20
X2kd
X
3
X2ke
6
16
18
18
17
6
7
X2kd
7
21 21
A
X1kf X1ke
X2kf
4
00344265-02
Siemens PLEA
A
19
X1ka
X2kb X2ka
10
END
X1kb
19
1
X212
15
A
26
27 28
29 30
31 32
X7kg
XX
8
20
40
AA-BBBB-CCCC
X2kf
X2kc
6
X
1
3
3
3
3
3
8
1
30mm
45
5
4
10
130mm
500mm
2
1
E
3
4
X
X2kg
E
D
C
B
3
35mm
8
9
5
X2kcX2ke
X2kf X2ka
X2ke
3
3
4
13
14
16
6
X211
1
7
8
X
F
B
12
4
X
X4ki
X
A
3
3
3
4
4
10
10
7
X2kb
5
X2kc
1
XX
X210
F
E
X1kc
X7ki
17
X4kg
X
X5kg X6kg
X1kg
X
8
9
10
E
12
B
C
D
11
X2kaX2kb
X
X3kg
0V
0V
0V
0V
0V
4
A2 A1
A6
4
X2ki
420mm
X3ki
2345
01
01
02
Leh
Ha
Ha
X5ki X6ki
C
67
Date
Check.
Author
Creat. byCreat. f.Orig.NameModified DateStatus Stand.
Sh.
Sheet
SMD Placement System SIPLACE 80S20/S23
Document status
Product status
Function status
Terminal panel, lefthand side
Note 3:
Length for cable ducts +/- 5mm !
CCCC = series number
BBBB = date (year/month/day)
AA = manufacturer/location
VA-F-510-001 guideline
Font size: 2.5mm, material
Assembly inscription acc. to
Scotchcal 3698-E
(Color A1 RAL 9006)
acc. to SN 37040
=
SIEMENS AG
+
acc. to SN 01007
acc. to construction specs 00343603, sh. 2
DIN 125 washer
Screw
SN 70093 contact washer
DIN 439 nut
Annular cable lug
Ground connection
DIN 7980 split washer
DIN 439 nut
C: ground label
(ye&gn)
B: inspection label
Note 1:
to be fitted:
A: identification label
The following labels have
(Please note: X means to break off one rib from the cable duct)
Cable duct: 65x30 l=425mm
Cable duct: 65x46 l=425mm
Cable duct: 65x30 l=400mm
(Please note: XXX means to break off three ribs from the cable duct)Cable duct: 65x30 l=325mm
(Please note: X means to break off one rib from the cable duct)
Cable duct: 65x46 l=425mm
3 SIPLACE 80S-20 Circuit Diagrams 86
00200034-040101LD3 Optical decoupling unit
04.05.1999
Haas
Optical decoupling unit
01 Deu
04.05.99
GND 24V
X1 9
K1
13
6
9
1 2 3
JP2
X5 8
1413
GND 24V
GND 24V
10 11 12
5
6
7
X5
X5
X5
GND 24V
Received
Permission
151413X3
65
Permission
Received
MP2
MP1
R1
C1
Request
GND n-1
19 20
Request
U1
MP4
GND 24V
11
loop
K1
1
7
Fault signal
12
R2
C2
Transferred
18
preceding station
To
U2
6
Transferred
2K7
R8
2K7
R7
MP3
2K7
R5
2K7
R6
Permission
Received
Transferred
Request
+24VDC
Spare
Spare
Spare
1098
+30VDC unswitched
+24VDC
123
GND 24V
X7
X7
X7
X7
X7
1
2
3
4
5
6X7
Spare
Spare
Spare
Spare
Spare
Spare
1
2
3
JP1
MP9
V2
+-
V1
+-
V3
+-
V4
+-
ye
ye
gn
gn
gn
gn
ye
ye
V8
V7
V5
V6
Spare
Spare
Spare
9810X4
+24VDC
GND 24V
+30VDC unswitched
564
2K7
R11
2K7
R12
2K7
R10
2K7
R9
Permission
Transferred
Request
Received
11
Fault signal
12
Loop
succeeding station
To
R3
C3
Permission
15
7
Permission
U3
MP5
GND 24V
R4
C4
Received
GND n+1
1413
8
Received
U4
MP6
Request
GND 24V
Transferred
18 19 20
7
Transferred
Request
MP7
MP8
X1 8X2 5
Deu
04.05.99
04
Output 1
Output 2
Output 3
Output 4Output 4
Output 3
Output 2
Output 1
6
7
8
X6
X6
X6
5 X6
12111091234
+ X6
+24VDC
+24VDC
+24VDC
+24VDC
Input 1
Input 2
Input 3
Input 4 Input 4
Input 3
Input 2
Input 1
+24VDC
U
U
X5
X5
P
P
M
X5
X5
X5
M X5
+30VDC unswitched
+30VDC unswitched
GND 24V
GND 24V
+24VDC
+24VDC
G X5
1234
GND 24V
GND 24V
GND 24VX6
X6
X6 -
-
-
GND 24V
GND 24V
X2 13 14
+30VDC switched
+30VDC switched
+30VDC switched
+30VDC switched
+30VDC switched
00200034-040101LD3
01
Deu
04.05.99
Function status
34
12
34
12
+-
+-
+-
+-
34
21
34
21
Name Stand.
Author
Urspr./Ers.f./Ers.d.
Sh.
Sh.DateModifiedStatus
Date
Check.
1816151413121110987654321 17
PL EA 1E
SIEMENS AG
Product status
Document status
SMD Placement System Siplace 80S20
1
1
Sh.
Sh.
D3
D2
D1
0.1uF 0.1uF 0.1uF 0.1uF
1K5 1.1W
1K5 1.1W
1K5 1.1W
1K5 1.1W
See page 104