00194329-03 - 第143页
Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 143 : Loosen the screws in the clamp on the placement head. 2 : Detach the compressed air hoses on the placeme nt head as follo…

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
142
: Unplug all the cables on the top side of the head board.
2
2
: Loosen all the fixing screws on the head board. You may have to remove the piggy-back
boards in order to do this.
: Now remove the head board.
: Unplug the ribbon cable connectors on the underside of the head board.
2
2
2
2
2
2
2
Disconnect the cables

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
143
: Loosen the screws in the clamp on the placement head.
2
: Detach the compressed air hoses on the placement head as follows:
HS-50: on the vacuum generator,
HS-60: on the clamp strip.
2
2 screws
HS-50
HS-60
Detach the hoses (HS-60)
Detach the hoses
(HS-50)

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
144
: Loosen the two screws used to screw the plate to the hoses/cables on the gantry arm. Do not
release the clamps.
2
: Loosen the screw in the cable and hose carrier beside the idler pulley.
2
2
The cable and hose carrier is now completely detached from the machine and can be removed.2
2
Screws
Loosen screw