00194329-03 - 第165页
Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 165 : Remove the Y -bumper (1 screw). 2 2 : Remove the plate with the interface box. : Detach all the ribbon cables in the cabl…

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
164
: Remove the stops for the protective covers.
2
2
: Remove the protective covers on each side and set them down in a suitable place.
2
Stop for
protective
cover

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
165
: Remove the Y-bumper (1 screw).
2
2
: Remove the plate with the interface box.
: Detach all the ribbon cables in the cable and hose carrier from the gantry conversion board
(see photograph).
: Remove the cable ties.
: Pull the cables carefully up to remove.
2
Screw
Cable tray
Detach all the connectors of the
ribbon cables
Interface box
Plate with interface box (2 screws)

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
166
: Loosen the screws for the cable guiding chain on both sides.
: Remove the cable guiding chain together with the nylon tape.
2
2
: Compare the lengths of the new and old cable guide chain. If they are not exactly the same,
the air hoses MUST be replaced as well.
2
If this is not the case, the air hoses MUST be replaced as well, otherwise they will not be long
enough to allow them to be connected correctly. 2
2
: Loosen the two screws on the strain relief for the Y-axis cable and hose carrier.
2
2
2
2