00194329-03 - 第169页

Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 169 : Loosen the fixing screws for th e head board and lif t the board away fro m the locating pins. The cables on the top of t…

100%1 / 198
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
168
: Remove the three pins of the strain relief using a suitable tool (e.g. grooved hammer head).
2
Do not use pliers to do this, otherwise the surface of the fixing pins or the ribbon cable might be
damaged. 2
2
2
: Remove the 3 cable clamp on the gantry arm.
2
2
2
Strain relief
Groove
Remove clamps
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
169
: Loosen the fixing screws for the head board and lift the board away from the locating pins. The
cables on the top of the board can remain plugged in.
2
2
: Unplug all the cables on the underside of the head board.
Note which cables are allocated to which connectors for when you fit the new cable set.
2
2
2
2
2
2
Unscrew the head board
Disconnect the cables
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
170
2
The following step may be omitted if the air hoses do not have to be replaced. 2
2
: Detach the compressed air hoses on the vacuum generator for the placement head.
Hoses 1 and 2 are not connected on the S machines.
Note which hose is allocated to which connector so that you can reattach them correctly.
2
2
Detach compressed air hoses